Preliminary analysis of the forces on the thoracic cage of patients with pectus excavatum after the Nuss procedure
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
885 | en_US |
dc.citation.issue |
7 | en_US |
dc.citation.spage |
881 | en_US |
dc.citation.volume |
23 | en_US |
dc.citation.woscount |
13 | |
dc.contributor.author |
Chang, Pei Yeh | en_US |
dc.contributor.author |
Hsu, Zhen-Yu | en_US |
dc.contributor.author |
Chen, Da-Pan | en_US |
dc.contributor.author |
Lai, Jin-Yao | en_US |
dc.contributor.author |
Wang, Chao-Jan | en_US |
dc.contributor.department |
機械工程學系 | zh_TW |
dc.contributor.department |
Department of Mechanical Engineering | en_US |
dc.date.accessioned |
2014-12-08T15:11:07Z | |
dc.date.available |
2014-12-08T15:11:07Z | |
dc.date.issued |
2008-08-01 | en_US |
dc.description.abstract |
Background. The Nuss procedure corrects pectus excavatum using a pre-bent bar that generates stress on the chest wall. To investigate the biomechanical effects after the Nuss procedure, we designed a three-dimensional finite element analysis model to analyze the distribution of stress and strain induced in the chest wall. Methods. Three patients with pectus excavatum aged 8, 7, and 7 years, were enrolled in this study. The greatest upward displacements of their sternums after the operation were measured from computed tomography images and chest X-ray films. Based on these displacements, we constructed three finite element analysis models for analyzing biomechanical changes in the thoracic cage after the Nuss procedure. Findings. The simulation results indicated that greatest strain occurred at the third through seventh cartilages, especially where they join the sternum and ribs. A high bilateral stress distribution was also found over the backs of the third to the seventh ribs near the vertebral column. Interpretation. The stress and strain induced by the Nuss procedure can be analyzed using our finite element analysis model. Although the stress and strain may have some influence on chest and spine development, a more detailed finite element analysis model is recommended for future study to improve the accuracy of our simulation results. (c) 2008 Elsevier Ltd. All rights reserved. | en_US |
dc.identifier.doi |
10.1016/j.clinbiomech.2008.02.010 | en_US |
dc.identifier.issn |
0268-0033 | en_US |
dc.identifier.journal |
CLINICAL BIOMECHANICS | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1016/j.clinbiomech.2008.02.010 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/8520 | |
dc.identifier.wosnumber |
WOS:000258369300005 | |
dc.language.iso |
en_US | en_US |
dc.subject |
finite element analysis | en_US |
dc.subject |
pectus excavatum | en_US |
dc.subject |
nuss procedure | en_US |
dc.subject |
biomechanical simulation | en_US |
dc.subject |
stress and strain | en_US |
dc.title |
Preliminary analysis of the forces on the thoracic cage of patients with pectus excavatum after the Nuss procedure | en_US |
dc.type |
Article | en_US |
檔案
- 000258369300005.pdf (423.1 KB, Adobe PDF)
所屬典藏: 期刊論文
引用此條目
Chang, P. Y., Hsu, Z.-Y., Chen, D.-P., Lai, J.-Y., & Wang, C.-J. (2008). Preliminary analysis of the forces on the thoracic cage of patients with pectus excavatum after the Nuss procedure. CLINICAL BIOMECHANICS, 23(7), 881–885. https://doi.org/10.1016/j.clinbiomech.2008.02.010
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/8520