Comparison of cleanroom samplers for inorganic airborne molecular contaminants
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
861 | en_US |
dc.citation.issue |
4 | en_US |
dc.citation.spage |
842 | en_US |
dc.citation.volume |
43 | en_US |
dc.citation.woscount |
5 | |
dc.contributor.author |
Lin, I-Kai | en_US |
dc.contributor.author |
Bai, Hsunling | en_US |
dc.contributor.author |
Liu, Cheng-Chang | en_US |
dc.contributor.author |
Wu, Bi-Jun | en_US |
dc.contributor.department |
環境工程研究所 | zh_TW |
dc.contributor.department |
Institute of Environmental Engineering | en_US |
dc.date.accessioned |
2014-12-08T15:12:33Z | |
dc.date.available |
2014-12-08T15:12:33Z | |
dc.date.issued |
2008-03-01 | en_US |
dc.description.abstract |
The performances of inorganic airborne molecular contaminants (AMCs) via silica gel tubes, impingers, and diffusion denuder sampler (DDS) were compared in a cleanroom. The results showed silica gel tubes were not applicable for cleanroom sampling due to high blanks. While with optimal sampling conditions both impingers and DDS have much better performances, of which DDS has the lowest detection limits of the method for HF, HCl, HNO2, HNO3, SO2, and NH3 gases to be 0.15, 0.11, 0.13, 0.03, 0.07, and 0.42 mu g/m(3), respectively. Results indicated no significant difference for the HF and SO42- concentrations made by the DDS and impingers. | en_US |
dc.identifier.doi |
10.1080/01496390701870580 | en_US |
dc.identifier.issn |
0149-6395 | en_US |
dc.identifier.journal |
SEPARATION SCIENCE AND TECHNOLOGY | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1080/01496390701870580 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/9643 | |
dc.identifier.wosnumber |
WOS:000254394700009 | |
dc.language.iso |
en_US | en_US |
dc.subject |
airborne molecular contamination (AMC) | en_US |
dc.subject |
cleanroom | en_US |
dc.subject |
micro-contamination | en_US |
dc.subject |
semiconductor device | en_US |
dc.subject |
diffusion denuder sampler (DDS) | en_US |
dc.subject |
impinger air sampler | en_US |
dc.title |
Comparison of cleanroom samplers for inorganic airborne molecular contaminants | en_US |
dc.type |
Article | en_US |
檔案
- 000254394700009.pdf (358.7 KB, Adobe PDF)
所屬典藏: 期刊論文
引用此條目
Lin, I.-K., Bai, H., Liu, C.-C., & Wu, B.-J. (2008). Comparison of cleanroom samplers for inorganic airborne molecular contaminants. SEPARATION SCIENCE AND TECHNOLOGY, 43(4), 842–861. https://doi.org/10.1080/01496390701870580
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/9643