Plasma treatment effects on hydrogenated amorphous carbon films prepared by plasma-enhanced chemical vapor deposition
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
DOI
10.1016/j.jpcs.2007.07.126
Abstract
When hydrogenated amorphous carbon (a-C:H) films are deposited by a radio frequency (RF; 13.56MHz) glow discharge system, their properties can be significantly affected by RF power input at deposition. Furthermore, the hydrogen content in the a-C:H films will be decreased in the postdeposition plasma treatment. This study investigated the effects of plasma input at deposition and postdeposition plasma treatment on the resulting film properties of a-C:H films. Atomic force microscopy (AFM) was employed to detect the surface roughness of the plasma-enhanced chemical vapor deposition (PECVD) a-C:H films. Raman spectroscopy was employed to determine the hydrogen concentration as well as the tetrahedral and trigonal bondings associated with C-H bond. The Raman analysis results Suggested the occurrence of a higher degree of structural order in the sp(2) lattice of the well plasma-treated a-C:H films. (c) 2007 Elsevier Ltd. All rights reserved.