A FIELD-STUDY OF 3 COLLOCATED AMBIENT PM10 SAMPLERS

Loading...
Thumbnail Image

Authors

Journal Title

Journal ISSN

Volume Title

Publisher

DOI

Abstract

The performances of three ambient PM10 samplers were studied at three monitoring stations in Taiwan. It was found that differences in the daily measured PM10 concentrations of the SA 1200 and Wedding high-volume samplers are now within +/- 10% since the former now has a closer cut-point to the latter than in the earlier SA 321 A model. The Wedding beta gauge automatic sampler was found to be applicable in rainy and humid weather conditions in Taiwan. Its daily PM10 concentrations are typically within +/- 10% of those of the Wedding high-volume sampler. The particle loading effect of Wedding high-volume and beta gauge samplers was found to be important. To avoid sampling errors due to the loading effect with ambient PM10 samplers, they must be cleaned regularly at an interval depending on the ambient particulate level.