Title: The Study of the Inductive Coil to the Acoustic Performance of Electromagnetic Driven Microspeaker
Authors: Weber, C.
Chen, Y. C.
Cheng, Y. T.
電子工程學系及電子研究所
Department of Electronics Engineering and Institute of Electronics
Keywords: hearing aids;microspeaker;coil placement;MEMS;audio
Issue Date: 1-Jan-2014
Abstract: Electromagnetic driven MEMS speakers using Polydimethylsiloxane (PDMS) membrane have been investigated to obtain a better sound pressure level (SPL) respond in low frequency regime. The comparison between measure and COMSOL simulation of fabricated microspeakers shows that the copper coil and its electrical feedthrough have a strong effect on the rigidity of the membrane thus on the SPL. Without considering the feedthrough effect, wide bandwidth starting at low frequency can be obtained while the coil is placed in the centre of the membrane, whereas placing the coil close to the membrane border instead will give a better response in low frequency with feedthrough effect (C) 2014 Published by Elsevier Ltd.
URI: http://dx.doi.org/10.1016/j.proeng.2014.11.734
http://hdl.handle.net/11536/136417
ISSN: 1877-7058
DOI: 10.1016/j.proeng.2014.11.734
Journal: 28TH EUROPEAN CONFERENCE ON SOLID-STATE TRANSDUCERS (EUROSENSORS 2014)
Volume: 87
Begin Page: 384
End Page: 387
Appears in Collections:Conferences Paper


Files in This Item:

  1. 4f26eedf0338af95dcd5764a6729007e.pdf

If it is a zip file, please download the file and unzip it, then open index.html in a browser to view the full text content.