Title: Achromatic design in the illumination system for a mini projector with LED light source
Authors: Pan, Jui-Wen
Lin, Sheng-Han
光電系統研究所
生醫電子轉譯研究中心
Institute of Photonic System
Biomedical Electronics Translational Research Center
Issue Date: 15-Aug-2011
Abstract: We provide a novel achromatic design in the illumination system for a mini projector with an LED light source. The lateral color aberration at the corners of the DMD active area can be reduced to 0.48 mu m by our compact ATIR prism. The total prism size is 4091 mm(3). The spot sizes at the corner and the edge are also controlled under 198 mu m. Moreover, we use a light pipe for color uniformity at the center of the DMD active area. Under the two components for color uniformity, the Delta u' v' is well controlled under 0.016 by a 20 mm length of light pipe. The illuminance uniformity at the active area of the DMD chip is higher than 92.8%. The optical efficiency of the light pipe is 94.1%. (C) 2011 Optical Society of America
URI: http://dx.doi.org/10.1364/OE.19.015750
http://hdl.handle.net/11536/20267
ISSN: 1094-4087
DOI: 10.1364/OE.19.015750
Journal: OPTICS EXPRESS
Volume: 19
Issue: 17
Begin Page: 15750
End Page: 15759
Appears in Collections:Articles


Files in This Item:

  1. 000293894900011.pdf

If it is a zip file, please download the file and unzip it, then open index.html in a browser to view the full text content.