Title: Seismic self-centering steel beam-to-column moment connections using bolted friction devices
Authors: Tsai, Keh-Chyuan
Chou, Chung-Che
Lin, Chi-Lon
Chen, Pei-Ching
Jhang, Sheng-Jhih
土木工程學系
Department of Civil Engineering
Keywords: post-tensioned connection;self-centering;friction device
Issue Date: 10-Apr-2008
Abstract: This paper first presents the force-deformation relationship of a post-tensioned (PT) steel beam-to-column connection constructed with bolted web friction devices (FDs). This paper then describes the test program conducted in the National Center for Research on Earthquake Engineering, Taiwan, on four bolted FDs and four full-scale PT beam-to-column moment connection subassemblies using the FDs. Tests confirm that (1) the hysteretic behavior of four bolted FDs is very stable, (2) the friction coefficient between the steel plate and the brass shim is about 0.34, (3) the proposed force-deformation relationships reasonably predict the experimental responses of the PT connections under cyclically increasing deformations up to a beam peak rotation of 0.05 rad, and (4) the decompression moments do not degrade as beam cyclic deformations increase. Copyright (C) 2007 John Wiley & Sons, Ltd.
URI: http://dx.doi.org/10.1002/eqe.779
http://hdl.handle.net/11536/9462
ISSN: 0098-8847
DOI: 10.1002/eqe.779
Journal: EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS
Volume: 37
Issue: 4
Begin Page: 627
End Page: 645
Appears in Collections:Articles


Files in This Item:

  1. 000254670400008.pdf

If it is a zip file, please download the file and unzip it, then open index.html in a browser to view the full text content.