標題: | Investigation of cell operation conditions for co tolerance improvement of PEMFC |
作者: | Chung, Chen-Chung Chen, Chiun-Hsun Weng, Der-Cheng Yan, Yi-Yie Lin, Hsiang-Hui 機械工程學系 Department of Mechanical Engineering |
關鍵字: | CO tolerance;PEMFC |
公開日期: | 1-十二月-2007 |
摘要: | The investigation is to experimentally study the transient CO poisoning test with different cell operation conditions. One is fixing the cell voltage and the other is fixing the current density. In the former condition, the voltages are fixed at 0.5, 0.6, 0.7V, respectively, whereas the current densities are fixed at 600, 1000, 1200mA/cm(2), respectively, in the latter one. In the transient poisoning test, the cell performance will be declined with time. The poisoned polarization curves are determined as soon as the performance subjected to CO poisoning reaches a steady state. Then, it will determine which one has a better performance in CO poisoning test and find out the difference between these two methods. With fixed cell voltage to perform transient CO poisoning test, it indicates that changing cell voltage cannot transform the stable poisoned polarization behaviors, whereas with fixed current density, it can get a better recovery performance at a fixed CO concentration (52.7ppm). |
URI: | http://hdl.handle.net/11536/10091 |
ISSN: | 0257-9731 |
期刊: | JOURNAL OF THE CHINESE SOCIETY OF MECHANICAL ENGINEERS |
Volume: | 28 |
Issue: | 6 |
起始頁: | 563 |
結束頁: | 569 |
顯示於類別: | 期刊論文 |