Analysis of evaporation of non-azeotropic refrigerants in a horizontal tube
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
827 | en_US |
dc.citation.issue |
10 | en_US |
dc.citation.spage |
817 | en_US |
dc.citation.volume |
16 | en_US |
dc.citation.woscount |
7 | |
dc.contributor.author |
Chiou, CB | en_US |
dc.contributor.author |
Lu, DC | en_US |
dc.contributor.author |
Wang, CC | en_US |
dc.contributor.department |
機械工程學系 | zh_TW |
dc.contributor.department |
Department of Mechanical Engineering | en_US |
dc.date.accessioned |
2014-12-08T15:02:20Z | |
dc.date.available |
2014-12-08T15:02:20Z | |
dc.date.issued |
1996-10-01 | en_US |
dc.description.abstract |
Based on the two-phase separated model, a detailed one-dimensional model for binary mixtures had been proposed to study the in-tube evaporation in a horizontal tube. The present model can predict the detailed variation of the composition, temperature, heat transfer rate and pressure drop of various binary mixtures under constant heat flux, counter-flow, or parallel-flow conditions. The predicted results agree favorably with the Takamatsu et al. [Int. J. Neat Mass Transfer 36, 3555-3563 (1993)] and Jung et al. [Exp. Heat Transfer 2, 237-255 (1989)] experimental data. Also, it is found that the full evaporation of the non-azeotropic refrigerants may require a corresponding temperature higher than the saturation temperature of the less volatile component. The non-linear variation of the property plays an important role in the heat transfer and pressure drop characteristics of the refrigerant mixtures. Copyright (C) 1996 Elsevier Science Ltd. | en_US |
dc.identifier.doi |
10.1016/1359-4311(95)00089-5 | en_US |
dc.identifier.issn |
1359-4311 | en_US |
dc.identifier.journal |
APPLIED THERMAL ENGINEERING | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1016/1359-4311(95)00089-5 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/1011 | |
dc.identifier.wosnumber |
WOS:A1996VB16500004 | |
dc.language.iso |
en_US | en_US |
dc.subject |
non-azeotropic refrigerants | en_US |
dc.subject |
evaporation | en_US |
dc.subject |
model | en_US |
dc.title |
Analysis of evaporation of non-azeotropic refrigerants in a horizontal tube | en_US |
dc.type |
Article | en_US |
檔案
- A1996VB16500004.pdf (583.7 KB, Adobe PDF)
所屬典藏: 期刊論文
引用此條目
Chiou, C., Lu, D., & Wang, C. (1996). Analysis of evaporation of non-azeotropic refrigerants in a horizontal tube. APPLIED THERMAL ENGINEERING, 16(10), 817–827. https://doi.org/10.1016/1359-4311(95)00089-5
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/1011