Simplified PWM With Switching Constraint Method to Prevent Circulating Currents for Paralleled Bidirectional AC/DC Converters in Grid-Tied System Using Graphic Analysis

檔案

本條目沒有附加檔案。

至出版者網站查看(DOI) ›

日期

2015-07-01

類型

期刊名稱

IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS

卷期與頁次

第 62 卷,頁 4573–4586

ISSN

0278-0046

語言

英文

摘要

In this paper, a simplified pulsewidth modulation with switching constraint control scheme is proposed to eliminate the circulating currents for bidirectional paralleled ac/dc converters in grid-tied system. The proposed control scheme can reduce the circulating currents and does not need additional current sensors and communication device among paralleled converters compared with conventional methods. Therefore, the paralleled system cost can be reduced. In addition, the current shaping and sharing between the paralleled converters can be well accomplished so that the overall performance of the paralleled converter system can be raised. Furthermore, the dc, ac, and self-generated circulating currents are clearly analyzed by graphics, and the synchronous circulating currents are first explored. Finally, a prototype system is constructed, and the proposed control scheme is implemented using a Spartan-3E XC3S250E FPGA. Both simulation and experimental results verify the validity of the proposed theory and control scheme.

所屬典藏

期刊論文
顯示完整詮釋資料 統計資料

引用此條目

Liao, Y.-H., & Chen, H. C. (2015). Simplified PWM With Switching Constraint Method to Prevent Circulating Currents for Paralleled Bidirectional AC/DC Converters in Grid-Tied System Using Graphic Analysis. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 62, 4573–4586. https://doi.org/10.1109/TIE.2014.2352597

BibTeX RIS

引用文字依 APA 第 7 版格式自動產生,使用前請再核對。

分享

永久網址:https://ir.lib.nycu.edu.tw/handle/11536/124766