Microstructures of fire-damaged concrete

檔案

本條目沒有附加檔案。

日期

1996-05-01

類型

期刊名稱

ACI MATERIALS JOURNAL

卷期與頁次

第 93 卷第 3 期,頁 199–205

ISSN

0889-325X

語言

英文

摘要

This paper presents results of scanning electron microscopy (SEM) and stereo microscopy investigations of fire-damaged concrete. Samples were either taken from concrete that was subjected to heating and cooling of controlled temperatures in the laboratory or removed from concrete and masonry units exposed to fires in the field. By compiling SEM photographs, a clear chronological pattern of a failure mechanism can be visualized. For instance, the morphologies of hydrates from room temperature up to 900 C and reformation of calcium hydroxides (CH) during cooling all have distinguished morphological appearances of their own. Such visual information that would otherwise be impossible to see with the naked eye will help scientists and engineers understand concrete behaviors in fire. This study has focused on microstructures of cement pastes/aggregates, microvoids/cracks, and separation of the cement paste from aggregates in heated concrete samples. An application of lincrete, a type of polyester-polymer concrete developed at National Chiao Tung University, is included to demonstrate the use of a cement-based polymer mortar in the rehabilitation process of fire-damaged concrete.

所屬典藏

期刊論文
顯示完整詮釋資料 統計資料

引用此條目

Lin, W., Lin, T., & PowersCouche, L. (1996). Microstructures of fire-damaged concrete. ACI MATERIALS JOURNAL, 93(3), 199–205. https://ir.lib.nycu.edu.tw/handle/11536/1294

BibTeX RIS

引用文字依 APA 第 7 版格式自動產生,使用前請再核對。

分享

永久網址:https://ir.lib.nycu.edu.tw/handle/11536/1294