Finite Element Analysis of an Ultrasonic Vibration Device at High Temperatures
檔案
本條目沒有附加檔案。
日期
2016-06
系所
期刊名稱
JOURNAL OF THE CHINESE SOCIETY OF MECHANICAL ENGINEERS
卷期與頁次
第 37 卷第 3 期,頁 193–200
ISSN
0257-9731
語言
英文
摘要
Ultrasonic-vibration-assisted forming has been extensively adopted in plastic manufacturing processes. Ultrasonic vibration contributes to enhancing material formability and product quality and to reducing manufacturing costs by improving frictional conditions and increasing the temperature of materials. However, designing a suitable ultrasonic vibration system for processes conducted at high working temperatures, such as the ultrasonic vibration-assisted glass hot embossing process, is difficult because of complex thermal boundaries and material properties. In this study, an ultrasonic vibration system that can be used at high working temperatures was analyzed using the finite element method and ANSYS commercial software. The simulation results obtained from thermal, modal, and harmonic response analyses were compared with experimental measurements to confirm the validity of the numerical analysis. The resulting finite element module can be used in designing the components of ultrasonic vibration devices that can be used at high working temperatures.
所屬典藏
期刊論文引用此條目
Lan Phuong Nguyen, Tsai, Y.-P., Hung, J.-C., Hsieh, Y.-C., & Hung, C. (2016). Finite Element Analysis of an Ultrasonic Vibration Device at High Temperatures. JOURNAL OF THE CHINESE SOCIETY OF MECHANICAL ENGINEERS, 37(3), 193–200. https://ir.lib.nycu.edu.tw/handle/11536/134039
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/134039