UV-LIGA interferometer biosensor based on the SU-8 optical waveguide
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
389 | en_US |
dc.citation.issue |
2 | en_US |
dc.citation.spage |
383 | en_US |
dc.citation.volume |
120 | en_US |
dc.citation.woscount |
35 | |
dc.contributor.author |
Shew, BY | en_US |
dc.contributor.author |
Kuo, CH | en_US |
dc.contributor.author |
Huang, YC | en_US |
dc.contributor.author |
Tsai, YH | en_US |
dc.contributor.department |
機械工程學系 | zh_TW |
dc.contributor.department |
Department of Mechanical Engineering | en_US |
dc.date.accessioned |
2014-12-08T15:19:07Z | |
dc.date.available |
2014-12-08T15:19:07Z | |
dc.date.issued |
2005-05-17 | en_US |
dc.description.abstract |
SU-8 resist was used as a core/cladding waveguide material to fabricate a Mach-Zehnder interferometer (MZI) for biochemical sensing. The refractive index of the SU-8 resist was fine-tuned with a Delta n of 0.004 for single-mode transmission. The UV lithography processes of the SU-8 resist were also optimized to pattern the high resolution (1 mu m) and high aspect ratio (A(R) = 6) Y-branch structure of the optical interferometer. Optical measurements reveal that the SU-8 MZI chip can efficiently transmit the NIR laser (lambda = 13 10 mu) with a total loss less than 6 dB. When one branch of the MZI is in contact with the analyte, the interfered intensity stabilizes after the soaking time exceeds 5 min. NaCl solution with a concentration of 10(-9) g/l can be detected using the SU-8 MZI chip. In the future, the polymer MZI chip can be mass-produced by molding process (or the LIGA process). The low-cost, label-free, real-time and high-sensitivity MZI chip will benefit many applications related to biological, environmental and industrial detection. (c) 2005 Elsevier B.V. All rights reserved. | en_US |
dc.identifier.doi |
10.1016/j.sna.2005.01.004 | en_US |
dc.identifier.issn |
0924-4247 | en_US |
dc.identifier.journal |
SENSORS AND ACTUATORS A-PHYSICAL | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1016/j.sna.2005.01.004 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/13705 | |
dc.identifier.wosnumber |
WOS:000229298200012 | |
dc.language.iso |
en_US | en_US |
dc.subject |
optical waveguide | en_US |
dc.subject |
interferometer | en_US |
dc.subject |
biochemical sensor | en_US |
dc.subject |
SU-8 resist | en_US |
dc.subject |
LIGA process | en_US |
dc.title |
UV-LIGA interferometer biosensor based on the SU-8 optical waveguide | en_US |
dc.type |
Article | en_US |
檔案
- 000229298200012.pdf (291.0 KB, Adobe PDF)
所屬典藏: 期刊論文
引用此條目
Shew, B., Kuo, C., Huang, Y., & Tsai, Y. (2005). UV-LIGA interferometer biosensor based on the SU-8 optical waveguide. SENSORS AND ACTUATORS A-PHYSICAL, 120(2), 383–389. https://doi.org/10.1016/j.sna.2005.01.004
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/13705