UV-LIGA interferometer biosensor based on the SU-8 optical waveguide
檔案
- 000229298200012.pdf (291.0 KB, Adobe PDF)
日期
2005-05-17
類型
系所
期刊名稱
SENSORS AND ACTUATORS A-PHYSICAL
卷期與頁次
第 120 卷第 2 期,頁 383–389
ISSN
0924-4247
語言
英文
摘要
SU-8 resist was used as a core/cladding waveguide material to fabricate a Mach-Zehnder interferometer (MZI) for biochemical sensing. The refractive index of the SU-8 resist was fine-tuned with a Delta n of 0.004 for single-mode transmission. The UV lithography processes of the SU-8 resist were also optimized to pattern the high resolution (1 mu m) and high aspect ratio (A(R) = 6) Y-branch structure of the optical interferometer. Optical measurements reveal that the SU-8 MZI chip can efficiently transmit the NIR laser (lambda = 13 10 mu) with a total loss less than 6 dB. When one branch of the MZI is in contact with the analyte, the interfered intensity stabilizes after the soaking time exceeds 5 min. NaCl solution with a concentration of 10(-9) g/l can be detected using the SU-8 MZI chip. In the future, the polymer MZI chip can be mass-produced by molding process (or the LIGA process). The low-cost, label-free, real-time and high-sensitivity MZI chip will benefit many applications related to biological, environmental and industrial detection. (c) 2005 Elsevier B.V. All rights reserved.
所屬典藏
期刊論文引用此條目
Shew, B., Kuo, C., Huang, Y., & Tsai, Y. (2005). UV-LIGA interferometer biosensor based on the SU-8 optical waveguide. SENSORS AND ACTUATORS A-PHYSICAL, 120(2), 383–389. https://doi.org/10.1016/j.sna.2005.01.004
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/13705