Seasonal variation of the underground cosmic muon flux observed at Daya Bay
檔案
本條目沒有附加檔案。
日期
2018-01-01
作者
類型
系所
期刊名稱
JOURNAL OF COSMOLOGY AND ASTROPARTICLE PHYSICS
ISSN
1475-7516
語言
英文
摘要
The Daya Bay Experiment consists of eight identically designed detectors located in three underground experimental halls named as EH1, EH2, EH3, with 250, 265 and 860 meters of water equivalent vertical overburden, respectively. Cosmic muon events have been recorded over a two-year period. The underground muon rate is observed to be positively correlated with the effective atmospheric temperature and to follow a seasonal modulation pattern. The correlation coefficient alpha, describing how a variation in the muon rate relates to a variation in the effective atmospheric temperature, is found to be alpha(EH1) = 0 : 362 +/- 0 : 031, alpha(EH2) = 0.433 +/- 0.038 and alpha(EH3) = 0.641 +/- 0.057 for each experimental hall.
所屬典藏
期刊論文引用此條目
An, F. P., Balantekin, A. B., Band, H. R., Bishai, M., Blyth, S., Cao, D., Cao, G. F., Cao, J., Chan, Y. L., Chang, J. F., Chang, Y., Chen, H. S., Chen, Q. Y., Chen, S. M., Chen, Y. X., Chen, Y., Cheng, J., Cheng, Z. K., Cherwinka, J. J., … Zou, J. H. (2018). Seasonal variation of the underground cosmic muon flux observed at Daya Bay. JOURNAL OF COSMOLOGY AND ASTROPARTICLE PHYSICS. https://doi.org/10.1088/1475-7516/2018/01/001