Droplet Size-Aware and Error-Correcting Sample Preparation Using Micro-Electrode-Dot-Array Digital Microfluidic Biochips
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
1391 | en_US |
dc.citation.spage |
1380 | en_US |
dc.citation.volume |
11 | en_US |
dc.contributor.author |
Li, Zipeng | en_US |
dc.contributor.author |
Lai, Kelvin Yi-Tse | en_US |
dc.contributor.author |
Chakrabarty, Krishnendu | en_US |
dc.contributor.author |
Ho, Tsung-Yi | en_US |
dc.contributor.author |
Lee, Chen-Yi | en_US |
dc.contributor.department |
電子工程學系及電子研究所 | zh_TW |
dc.contributor.department |
Department of Electronics Engineering and Institute of Electronics | en_US |
dc.date.accessioned |
2018-08-21T05:53:09Z | |
dc.date.available |
2018-08-21T05:53:09Z | |
dc.date.issued |
2017-12-01 | en_US |
dc.description.abstract |
Sample preparation in digital microfluidics refers to the generation of droplets with target concentrations for on-chip biochemical applications. In recent years, digital microfluidic biochips (DMFBs) have been adopted as a platform for sample preparation. However, there remain two major problems associated with sample preparation on a conventional DMFB. First, only a (1: 1) mixing/splitting model can be used, leading to an increase in the number of fluidic operations required for sample preparation. Second, only a limited number of sensors can be integrated on a conventional DMFB; as a result, the latency for error detection during sample preparation is significant. To overcome these drawbacks, we adopt a next generation DMFB platform, referred to as micro-electrode-dot-array (MEDA), for sample preparation. We propose the first sample-preparation method that exploits the MEDA-specific advantages of fine-grained control of droplet sizes and real-time droplet sensing. Experimental demonstration using a fabricated MEDA biochip and simulation results highlight the effectiveness of the proposed sample-preparation method. | en_US |
dc.identifier.doi |
10.1109/TBCAS.2017.2742548 | en_US |
dc.identifier.issn |
1932-4545 | en_US |
dc.identifier.journal |
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1109/TBCAS.2017.2742548 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/144328 | |
dc.identifier.wosnumber |
WOS:000419340300022 | en_US |
dc.language.iso |
en_US | en_US |
dc.subject |
Digital mirofluidics | en_US |
dc.subject |
micro-electrode-dot-array | en_US |
dc.subject |
sample preparation | en_US |
dc.subject |
optimization algorithm | en_US |
dc.subject |
error recovery | en_US |
dc.title |
Droplet Size-Aware and Error-Correcting Sample Preparation Using Micro-Electrode-Dot-Array Digital Microfluidic Biochips | en_US |
dc.type |
Article | en_US |
檔案
本條目沒有附加檔案。
所屬典藏: 期刊論文
引用此條目
Li, Z., Lai, K. Y.-T., Chakrabarty, K., Ho, T.-Y., & Lee, C.-Y. (2017). Droplet Size-Aware and Error-Correcting Sample Preparation Using Micro-Electrode-Dot-Array Digital Microfluidic Biochips. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 11, 1380–1391. https://doi.org/10.1109/TBCAS.2017.2742548
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/144328