Label-free protein quantitation by dielectric spectroscopy of dual-frequency liquid crystal
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
163 | en_US |
dc.citation.spage |
158 | en_US |
dc.citation.volume |
282 | en_US |
dc.citation.woscount |
0 | en_US |
dc.contributor.author |
Lin, Ching-Min | en_US |
dc.contributor.author |
Wu, Po-Chang | en_US |
dc.contributor.author |
Lee, Mon-Juan | en_US |
dc.contributor.author |
Lee, Wei | en_US |
dc.contributor.department |
光電學院 | zh_TW |
dc.contributor.department |
College of Photonics | en_US |
dc.date.accessioned |
2019-04-02T06:01:00Z | |
dc.date.available |
2019-04-02T06:01:00Z | |
dc.date.issued |
2019-03-01 | en_US |
dc.description.abstract |
A dual-frequency-liquid-crystal (DFLC)-based biosensor was developed and its frequency-dependent dielectric properties were exploited to detect and quantitate a protein standard, bovine serum albumin (BSA). By analyzing the dielectric spectra of DFLC in the presence of BSA at various concentrations, we found that the difference in dielectric permittivity between the high- and low-frequency regimes is correlated to BSA concentration, thereby permitting a DFLC-based protein quantitative method. The dielectric properties of DFLCs are fundamental in the design of liquid crystal displays and fast-switching devices. Results from this study demonstrate the extended potential of the frequency-revertible dielectric anisotropy of DFLC in biosensing and protein quantitation. | en_US |
dc.identifier.doi |
10.1016/j.snb.2018.11.047 | en_US |
dc.identifier.issn |
0925-4005 | en_US |
dc.identifier.journal |
SENSORS AND ACTUATORS B-CHEMICAL | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1016/j.snb.2018.11.047 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/148686 | |
dc.identifier.wosnumber |
WOS:000455090000020 | en_US |
dc.language.iso |
en_US | en_US |
dc.subject |
Dual-frequency liquid crystal | en_US |
dc.subject |
Dielectric spectroscopy | en_US |
dc.subject |
Protein | en_US |
dc.subject |
Bovine serum albumin | en_US |
dc.subject |
LC-based biosensor | en_US |
dc.title |
Label-free protein quantitation by dielectric spectroscopy of dual-frequency liquid crystal | en_US |
dc.type |
Article | en_US |
檔案
本條目沒有附加檔案。
所屬典藏: 期刊論文
引用此條目
Lin, C.-M., Wu, P.-C., Lee, M.-J., & Lee, W. (2019). Label-free protein quantitation by dielectric spectroscopy of dual-frequency liquid crystal. SENSORS AND ACTUATORS B-CHEMICAL, 282, 158–163. https://doi.org/10.1016/j.snb.2018.11.047
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/148686