Study of in vitro Diagnostic Preconcentration Technique via Surface Acoustic Wave Modified With the 54 MHz Communication Chip
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
395 | en_US |
dc.citation.spage |
392 | en_US |
dc.citation.woscount |
0 | en_US |
dc.contributor.author |
Chien, Ming-Hung | en_US |
dc.contributor.author |
Chiang, S. H. | en_US |
dc.contributor.author |
Chuang, Ching-Cheng | en_US |
dc.contributor.author |
Chen, Jung-Chih | en_US |
dc.contributor.department |
分子醫學與生物工程研究所 | zh_TW |
dc.contributor.department |
Institute of Molecular Medicine and Bioengineering | en_US |
dc.date.accessioned |
2019-05-02T00:26:46Z | |
dc.date.available |
2019-05-02T00:26:46Z | |
dc.date.issued |
2018-01-01 | en_US |
dc.description.abstract |
Particle separation and specimen preconcentration techniques are ones of the essential but time-consuming steps in the beginning of many biomedical sensing experiments or biosensor design. Hence, the study demonstrates a simple microfluidic system combined with surface acoustic wave (SAW) device, hoping to help researchers could spend less time on this routine process. A detachable and reusable acrylic microchannel is placed on the customized SAW chip which releases a 54 MHz SAW wave to separate 10 mu m particles from the others (1 mu m & 6 mu m) under the cut-off input power 23.4 dBm verified in the study and about 90% separation efficiency in average. | en_US |
dc.identifier.doi |
10.1109/IS3C.2018.00105 | en_US |
dc.identifier.isbn |
978-1-5386-7036-1 | en_US |
dc.identifier.issn |
2476-1052 | en_US |
dc.identifier.journal |
2018 INTERNATIONAL SYMPOSIUM ON COMPUTER, CONSUMER AND CONTROL (IS3C 2018) | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1109/IS3C.2018.00105 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/151712 | |
dc.identifier.wosnumber |
WOS:000462819400096 | en_US |
dc.language.iso |
en_US | en_US |
dc.subject |
Specimen preconcentration | en_US |
dc.subject |
Biosensor | en_US |
dc.subject |
Surface acoustic wave | en_US |
dc.subject |
Microchannel | en_US |
dc.subject |
Acoustofluidics | en_US |
dc.title |
Study of in vitro Diagnostic Preconcentration Technique via Surface Acoustic Wave Modified With the 54 MHz Communication Chip | en_US |
dc.type |
Proceedings Paper | en_US |
檔案
本條目沒有附加檔案。
所屬典藏: 會議論文
引用此條目
Chien, M.-H., Chiang, S. H., Chuang, C.-C., & Chen, J.-C. (2018). Study of in vitro Diagnostic Preconcentration Technique via Surface Acoustic Wave Modified With the 54 MHz Communication Chip. 2018 INTERNATIONAL SYMPOSIUM ON COMPUTER, CONSUMER AND CONTROL (IS3C 2018), 392–395. https://doi.org/10.1109/IS3C.2018.00105
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/151712