Fast Transient (FT) Technique With Adaptive Phase Margin (APM) for Current Mode DC-DC Buck Converters
檔案
- 000306922400004.pdf (3.13 MB, Adobe PDF)
日期
2012-10-01
類型
系所
期刊名稱
IEEE TRANSACTIONS ON VERY LARGE SCALE INTEGRATION (VLSI) SYSTEMS
卷期與頁次
第 20 卷第 10 期,頁 1781–1793
ISSN
1063-8210
語言
英文
摘要
This paper proposes a fast transient (FT) control with the adaptive phase margin (APM) to achieve good transient response in current-mode DC-DC buck converters at different load conditions. The overshoot/undershoot voltage and the transient recovery time are effectively reduced. The APM control can always maintain the system phase margin at an adequate value under different load conditions. That is, the compensation pole-zero pair is adapted to load current to extend the system bandwidth and get an adequate phase margin. Experimental results show the overshoot/undershoot voltage is smaller than 60 mV (3%) and transient period is smaller than 12 mu s as load current suddenly changes from 100 to 500 mA, or vice versa. Compared with conventional designs without any fast transient technique, the undershoot voltage and recovery time are enhanced by 45% and 85%, respectively.
所屬典藏
期刊論文引用此條目
Lee, Y.-H., Huang, S.-C., Wang, S.-W., & Chen, K.-H. (2012). Fast Transient (FT) Technique With Adaptive Phase Margin (APM) for Current Mode DC-DC Buck Converters. IEEE TRANSACTIONS ON VERY LARGE SCALE INTEGRATION (VLSI) SYSTEMS, 20(10), 1781–1793. https://doi.org/10.1109/TVLSI.2011.2163093
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/16840