Temporal focusing multiphoton microscopy with optimized parallel multiline scanning for fast biotissue imaging
檔案
-
10.1117_1.jbo.26.1.016501.pdf
(1.61 MB, Adobe PDF)
出版社正式版,依 CC BY 授權轉載,來源 https://doi.org/10.1117/1.jbo.26.1.016501
日期
2021-01-01
類型
系所
期刊名稱
Journal of Biomedical Optics
卷期與頁次
第 26 卷第 01 期,頁 1–16
ISSN
1083-3668
1560-2281
語言
英文
摘要
SIGNIFICANCE: Line scanning-based temporal focusing multiphoton microscopy (TFMPM) has superior axial excitation confinement (AEC) compared to conventional widefield TFMPM, but the frame rate is limited due to the limitation of the single line-to-line scanning mechanism. The development of the multiline scanning-based TFMPM requires only eight multiline patterns for full-field uniform multiphoton excitation and it still maintains superior AEC. AIM: The optimized parallel multiline scanning TFMPM is developed, and the performance is verified with theoretical simulation. The system provides a sharp AEC equivalent to the line scanning-based TFMPM, but fewer scans are required. APPROACH: A digital micromirror device is integrated in the TFMPM system and generates the multiline pattern for excitation. Based on the result of single-line pattern with sharp AEC, we can further model the multiline pattern to find the best structure that has the highest duty cycle together with the best AEC performance. RESULTS: The AEC is experimentally improved to 1.7 μm from the 3.5 μm of conventional TFMPM. The adopted multiline pattern is akin to a pulse-width-modulation pattern with a spatial period of four times the diffraction-limited line width. In other words, ideally only four π / 2 spatial phase-shift scans are required to form a full two-dimensional image with superior AEC instead of image-size-dependent line-to-line scanning. CONCLUSIONS: We have demonstrated the developed parallel multiline scanning-based TFMPM has the multiline pattern for sharp AEC and the least scans required for full-field uniform excitation. In the experimental results, the temporal focusing-based multiphoton images of disordered biotissue of mouse skin with improved axial resolution due to the near-theoretical limit AEC are shown to clearly reduce background scattering.
所屬典藏
期刊論文引用此條目
Chang, C.-Y., Lin, C.-Y., Hu, Y. Y., Tsai, S.-F., Hsu, F.-C., & Chen, S.-J. (2021). Temporal focusing multiphoton microscopy with optimized parallel multiline scanning for fast biotissue imaging. Journal of Biomedical Optics, 26(01), 1–16. https://doi.org/10.1117/1.jbo.26.1.016501
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/168964