Performance of Commercially Open Refrigerated Showcases with and without Ice Storage—A Case Study

檔案

本條目沒有附加檔案。

至出版者網站查看(DOI) ›

日期

2021-04-13

類型

期刊名稱

Processes

卷期與頁次

第 9 卷第 4 期,頁 683

ISSN

2227-9717

語言

英文

摘要

This study examines the applicability of the ice storage systems in the small commercial refrigerated showcases through experimental analysis. R-404A is used as the working fluid and various influence of parameter settings and improvements, are discussed in details. In the ice storage system, the condenser is changed from air-cooling (refrigeration mode) to an immersion type that is placed in an ice storage tank, the corresponding condensing temperature and pressure are reduced appreciably. This increased the efficiency and can effectively reduce the peak power consumption. The reduction of the condensing temperature and pressure increased the coefficient of performance (COP) from 3.6 (refrigeration mode) to 6.35 (melting mode), effectively enhancing the refrigeration efficiency. The results indicated that the ice storage system could effectively increase the coefficient of performance from 3.6 to 6.35 during ice melting when compared to the conventional refrigeration system. It also can shift approximately 35% of the power during peak hours and lower the energy cost by USD$ 17.13 per month.

所屬典藏

期刊論文
顯示完整詮釋資料 統計資料

引用此條目

Yang, K.-S., Chao, Y. S., Hsieh, C.-H., Chai, M.-L., & Wang, C.-C. (2021). Performance of Commercially Open Refrigerated Showcases with and without Ice Storage—A Case Study. Processes, 9(4), 683. https://doi.org/10.3390/pr9040683