Cervical spine immobilization does not interfere with nasotracheal intubation performed using GlideScope videolaryngoscopy: a randomized equivalence trial
檔案
本條目沒有附加檔案。
日期
2022-03-08
作者
類型
期刊名稱
Scientific Reports
卷期與頁次
第 12 卷第 1 期,頁 4041
ISSN
2045-2322
語言
英文
摘要
GlideScope-assisted nasotracheal intubation (NTI) has been proposed as an alternative to difficult orotracheal intubation for critical patients or those under cervical immobilization. We evaluated the difficulty of performing NTI using GlideScope under cervical orthosis. A total of 170 patients scheduled for elective cervical spinal surgery that required NTI were randomized to receive cervical immobilization using a cervical collar (collar group) or no cervical immobilization at all (control group) before anesthetic induction (group assignment at 1:1 ratio). All NTI during anesthetic induction were performed using the GlideScope. The primary outcome was time to intubation. The secondary outcomes were ease of intubation, including the necessity of auxiliary manipulations to assist intubation, and the nasotracheal intubation difficulty scale (nasoIDS). An exploratory analysis identified morphometric parameters as predictors of time to intubation, the necessity of auxiliary manipulations, and a nasoIDS score ≥ 4. For time to intubation, the mean difference (collar group-control) was - 4.19 s, with a 95% confidence interval (CI) of - 13.9 to 5.52 that lay within our defined equivalence margin of 16 s. Multivariate regressions precluded the association of cervical immobilization with a necessity for auxiliary manipulations (adjusted odds ratio [aOR] 0.53, 95% CI [0.26-1.09], P = 0.083) and a nasoIDS ≥ 4 (aOR 0.94 [0.84-1.05], P = 0.280). Among all morphometric parameters, the upper lip bite test class was predictive of a longer time to intubation (all analyses relative to class 1, 14 s longer for class 2, P = 0.032; 24 s longer for class 3, P = 0.070), increased necessity for auxiliary manipulation (aOR 2.29 [1.06-4.94], P = 0.036 for class 2; aOR 6.12 [1.04-39.94], P = 0.045 for class 3), and nasoIDS ≥ 4 (aOR 1.46 [1.14-1.89], P = 0.003 for class 3).The present study demonstrated that GlideScope achieved NTI in patients with or without cervical immobilization equivalently with respect to intubation time and ease.
所屬典藏
期刊論文引用此條目
Kuo, Y.-M., Lai, H.-Y., Tan, E. C.-H., Li, Y.-S., Chiang, T.-Y., Huang, S.-S., Huang, W.-C., & Chu, Y.-C. (2022). Cervical spine immobilization does not interfere with nasotracheal intubation performed using GlideScope videolaryngoscopy: a randomized equivalence trial. Scientific Reports, 12(1), 4041. https://doi.org/10.1038/s41598-022-08035-0
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/175193