Modification of a COVID-19 Patient Testing Station With a Semiautomatic Sanitization System
檔案
本條目沒有附加檔案。
日期
2022-05-21
類型
系所
期刊名稱
Annals of Work Exposures and Health
卷期與頁次
第 67 卷第 1 期,頁 160–162
ISSN
2398-7308
2398-7316
語言
英文
摘要
To the Editor: Globally, many different types of stations were built to enable testing of patients for COVID-19 while preventing exposures of medical personnel. In Taiwan, these were called non-exposure testing stations, and were kiosks that separated personnel from patients but included fixed gloves through which personnel could collect samples (Lee, 2020). Overall, there are two major limitations for operating an these testing stations. First, it is very difficult for medical personnel inside the stations to clean the outside zone by themselves (including the outside windows, gloves, tables, and chairs) without any additional assistance. Second, the sampling area in which the patient sits (or stands) might harbor some tiny fine droplets or aerosol particles that contain infectious virus, especially at those stations that do not have rigorous air circulation (i.e., inside a hospital or other buildings), and even outdoor sampling areas would need to be covered in the event of heavy rain or snow (Morawska et al., 2020). Although highly atomized disinfectants would be helpful in reducing the abundance of viruses in aerosol particles and the environment (by increasing humidity, chemical structure damage, or the scavenging effect) (Anand, 2020; Mecenas et al., 2020), they have not been widely applied in sampling stations. To solve the two major limitations and save manpower, we have developed a simple outdoor semiautomatic sanitization system that can be controlled by medical staff remotely with a simple setting to trigger the disinfection control circuit. The control circuit has two control modes: a fixed time-triggered control mode and a manual continuous-triggered control mode, which controls the sanitization pump to dispense disinfectant and works with multiple disinfection nozzles set above the sampling station. All the physical layouts of this system are created with 3D printing to advance time-to-market turnaround. The spray particle size of this system can range from 3 to 7 µm with a high atomization degree. Therefore, the disinfectant can quickly (less than 1 s) and naturally dry after spraying, and its atomization range is designed to adequately cover the sampling zone (Fig. 1). In our observation test, we found that our system could cover 100% of the area of sample zone sanitization (in 10 s) compared to medical staff only (65%, 30 s) and staff and patient cooperation (92%, 90 s) (Fig. 2). The system can cover 100% of the sampling area of zone sanitization with 10 s of spraying and provides a highly atomized design concept that might further sterilize the local air within the sampling zone. (A) The device can simply be hung (or placed on) the outside of the sampling zone. (B) The fluorescent spray particles can range from 3 to 7 µm with a high degree of atomization. (C) The original size of the system. Measurement of the median percentages of the sanitized area and the time cost in the sampling zone using fluorescent substances with a 20 W UV light (365 nm). (A) Medical staff only (65% of the area sanitized, 30 s); (B) staff and patient cooperation; (C) the outcome of cooperation (92% of the area sanitized, 90 s). All tests were repeated 5 times. Areas with no fluorescent response (reflex) were considered not cleaned. Notably, the 3D printing outdoor semiautomatic sanitization system is very easy to create and can even be made by the medical personnel. More importantly, it would be very useful in providing clean area for next patient, reducing concerns of the disease transmission. We thank Kuang Lung Shing Corporation for assistance with the experiment (providing fluorescent agents). No data were used in this study. This research was funded by the Ministry of Science and Technology of Taiwan (grant numbers 108-2221-E-400-003-MY3, and 110-2221-E-400-003-MY3); by the National Health Research Institutes of Taiwan (grant numbers NHRI-EX109-10829EI and NHRI-EX110-10829EI); and by the Ministry of Economic Affairs, Taiwan (grant number 110-EC-17-A-22-1650). The authors report that they have no potential conflicts of interest to disclose.
所屬典藏
期刊論文引用此條目
Lin, Y.-R., Zhong, N.-R., Huang, C.-C., Su, C.-P., Shen, C.-Y., & Liao, L.-D. (2022). Modification of a COVID-19 Patient Testing Station With a Semiautomatic Sanitization System. Annals of Work Exposures and Health, 67(1), 160–162. https://doi.org/10.1093/annweh/wxac036
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/176367