Failure evaluation of transmission tower with asymmetrical legs by Scaled–Down pushover experiment

檔案

本條目沒有附加檔案。

至出版者網站查看(DOI) ›

日期

2023-01-20

類型

期刊名稱

Engineering Structures

卷期與頁次

第 279 卷,頁 115511

ISSN

0141-0296
1873-7323

語言

英文

摘要

Power transmission towers are essential for the maintenance of daily living activities. Natural disasters such as wind storms, earthquakes, and landslides may damage these towers and cause considerable economic losses. To prevent these losses, transmission towers with asymmetrical legs, which have great flexibility on mountainous terrain, have been considered. Consequently, a scaled-down numerical model was first designed on the basis of a full-scale tower to understand the basic failure behavior of a transmission tower with asymmetrical legs. In addition, an experimental tower model was also conducted by pushover test to observe the failure mechanism and ductility. The failure mechanisms of the model were compared with the numerical simulations obtained from the finite element analysis. To accommodate the effects of asymmetrical legs, the component size should be increased appropriately for body extension. The results have demonstrated the feasibility of implementing transmission towers with asymmetrical legs at unique geographical locations.

所屬典藏

期刊論文
顯示完整詮釋資料 統計資料

引用此條目

Saddek, A. A., Lin, T.-K., & Sawadogo, W. L. A. (2023). Failure evaluation of transmission tower with asymmetrical legs by Scaled–Down pushover experiment. Engineering Structures, 279, 115511. https://doi.org/10.1016/j.engstruct.2022.115511

BibTeX RIS

引用文字依 APA 第 7 版格式自動產生,使用前請再核對。

分享

永久網址:https://ir.lib.nycu.edu.tw/handle/11536/178407