Biomechanical Differences of Coflex-F and Pedicle Screw Fixation in Stabilization of TLIF or ALIF Condition - A Finite Element Study
檔案
本條目沒有附加檔案。
日期
2010
類型
系所
期刊名稱
6TH WORLD CONGRESS OF BIOMECHANICS (WCB 2010), PTS 1-3
卷期與頁次
第 31 卷,頁 565–568
ISSN
1680-0737
ISBN
978-3-642-14514-8
語言
英文
摘要
Lumbar interbody fusion is a common procedure for treating lower back pain related to degenerative disc diseases. The Coflex-F is a recently developed interspinous spacer, the makers of which claim that it can provide stabilization similar to pedicle screw fixation. Therefore, this study compares the biomechanical behavior of the Coflex-F device and pedicle screw fixation with transforaminal lumbar interbody fusion (TLIF) or anterior lumbar interbody fusion (ALIF) surgeries. This study used a validated three-dimensional finite element model of the L1-L5 lumbar intact spine. To simulate TLIF surgery, left lateral total facetectomy and partial discectomy were performed at the L3/L4 segment of this intact model. An AVS-TL moon cage (Stryker Orthopaedics) was implanted in the L3/L4 segment and using a Coflex-F device or pedicle screw fixation. To simulate ALIF surgery, partial discectomy and total nuclectomy were performed at the L3/L4 segment of this intact model. A SynCage-Open cage (Synthes Spine, Inc.) was implanted into the L3/L4 segment and combined with a Coflex-F device or pedicle screw fixation. A 400 N follower load and a 10 Nm moment were applied to the intact model to mimic four physiological motions. All four implanted models were subjected to 400 N follower load and specific moments in accordance with the hybrid test method. The results show that the Coflex-F device combined with ALIF surgery can provide stability similar to that of pedicle screw fixation combined with TLIF or ALIF surgery. Also, both the posterior instrumentations (Coflex-F and pedicle screw fixation) combined with TLIF surgery had lower stability than combined with ALIF surgery.
關鍵詞
Interspinous spacerPedicle screw fixationTransforaminal lumbar interbody fusion (TLIF)Anterior lumbar interbody fusion (ALIF)Finite element所屬典藏
會議論文引用此條目
Lo, C. C., Tsai, K. J., Zhong, Z. C., & Hung, C. (2010). Biomechanical Differences of Coflex-F and Pedicle Screw Fixation in Stabilization of TLIF or ALIF Condition - A Finite Element Study. 6TH WORLD CONGRESS OF BIOMECHANICS (WCB 2010), PTS 1-3, 31, 565–568. https://ir.lib.nycu.edu.tw/handle/11536/18957
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/18957