Quantitative assessment of the tendon–pulley interface in trigger finger: a pilot feasibility study of a wearable electrical contact resistance sensor
檔案
-
10.1186_s13018-026-06990-2.pdf
(4.52 MB, Adobe PDF)
出版社正式版,依 CC BY-NC-ND 授權轉載,來源 https://doi.org/10.1186/s13018-026-06990-2
日期
2026-06-06
類型
系所
期刊名稱
Journal of Orthopaedic Surgery and Research
卷期與頁次
第 21 卷第 1 期,頁 487
ISSN
1749-799X
語言
英文
摘要
BACKGROUND: Trigger finger (stenosing tenosynovitis) reflects abnormal tendon-pulley mechanics, primarily at the A1 pulley; however, objective assessment during functional motion remains limited in routine clinical practice. We evaluated electrical contact resistance (ECR) from a wearable tactile sensor during standardized digit motion and examined its association with symptoms. METHODS: Nine participants with Green grade II-III trigger finger were prospectively enrolled. An origami-inspired pentagon-knot graphene-paper tactile sensor measured ECR over the A1 and A2 pulleys during repeated flexion-extension cycles. A 4-week intervention program (electrical stimulation plus infrared irradiation; three sessions per week) enabled repeated measurements. ECR and patient-reported outcomes were collected at weekly Tuesday assessments, with ECR recorded immediately before and after the session (ECRpre and ECRpost). Outcomes included pain (visual analog scale [VAS]) and triggering severity (ST), frequency (FT), and functional impact (FIT). Within-session change was defined as ΔECRsession = ECRpre - ECRpost. Analyses used linear mixed-effects models, repeated-measures correlation (rmcorr; rrm coefficient) and week-adjusted fixed-effects regression. RESULTS: Sensor placement and recording were feasible, with no adverse events. Across 27 paired weekly sessions (Weeks 1-4), ECR decreased from pre- to post-session at both pulleys (model-estimated mean ΔECRsession: A1 0.0795; A2 0.0990; both P < 0.001). A1 ECRpre declined over Weeks 1-4 (rrm = - 0.672; P = 0.0016). At matched weekly timepoints (N = 6; n = 24), A1 ECRpre correlated with VAS (rrm = 0.781; P < 0.001), FT (rrm = 0.578; P = 0.0095), and ST (rrm = 0.543; P = 0.0164), but not FIT (rrm = 0.165; P = 0.50). Larger A1 ΔECRsession values were associated with greater subsequent week-to-week pain improvement (rrm = 0.625; P = 0.0042). In a fixed-effects model adjusting for week, A1 ECRpre independently predicted VAS (β = 29.19; P = 0.018). CONCLUSIONS: Wearable ECR sensing was safe and feasible in this pilot study and demonstrated consistent within-session responsiveness. Clinically, motion-acquired ECR may serve as an objective adjunct for tracking session-level changes and week-to-week status with symptom scales. TRIAL REGISTRATION: Retrospectively registered at ChiCTR (ChiCTR2600120811 approved).
所屬典藏
期刊論文引用此條目
Huang, J.-F., Karmakar, R. S., Lin, Y.-C., Chao, J.-I., & Lu, Y.-W. (2026). Quantitative assessment of the tendon–pulley interface in trigger finger: a pilot feasibility study of a wearable electrical contact resistance sensor. Journal of Orthopaedic Surgery and Research, 21(1), 487. https://doi.org/10.1186/s13018-026-06990-2
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/195271