A Time-Frequency HRV Processor Using Windowed Lomb Periodogram

檔案

本條目沒有附加檔案。

日期

2010

類型

期刊名稱

DATABASE THEORY AND APPLICATION, BIO-SCIENCE AND BIO-TECHNOLOGY

卷期與頁次

第 118 卷,頁 273–282

ISSN

1865-0929

ISBN

978-3-642-17621-0

語言

英文

摘要

In this paper, a system for time-frequency analysis of heart rate variability (HRV) using windowed Lomb periodogram is proposed. The system is designed with considerations in SOC implementation for portable applications. Time-frequency analysis of HRV is achieved through a de-normalized Lomb periodogram with a sliding window configuration. The Lomb time-frequency distribution (TFD) is suited for power spectral density (PSD) analysis of unevenly spaced data and has been applied to the analysis of heart rate variability. The system has been implemented in hardware as an HRV processor and verified on FPGA. Artificial heart rate was used to evaluate the system as well as data from the MIT-BIH arrhythmia database and real EKG data. Simulations show that the proposed Lomb TFD is able to achieve better frequency resolution than short-time Fourier transform of the same hardware size.

所屬典藏

會議論文
顯示完整詮釋資料 統計資料

引用此條目

Tseng, S.-Y., & Fang, W.-C. (2010). A Time-Frequency HRV Processor Using Windowed Lomb Periodogram. DATABASE THEORY AND APPLICATION, BIO-SCIENCE AND BIO-TECHNOLOGY, 118, 273–282. https://ir.lib.nycu.edu.tw/handle/11536/20948