Inflow-weighted pulmonary perfusion: comparison between dynamic contrast-enhanced MRI versus perfusion scintigraphy in complex pulmonary circulation
檔案
-
10.1186_1532-429x-15-21.pdf
(1.03 MB, Adobe PDF)
出版社正式版,依 CC BY 授權轉載,來源 https://doi.org/10.1186/1532-429x-15-21
日期
2013-01-01
作者
類型
期刊名稱
Journal of Cardiovascular Magnetic Resonance
卷期與頁次
第 15 卷第 1 期,頁 21
ISSN
1097-6647
1532-429X
語言
英文
摘要
BACKGROUND: Due to the different properties of the contrast agents, the lung perfusion maps as measured by 99mTc-labeled macroaggregated albumin perfusion scintigraphy (PS) are not uncommonly discrepant from those measured by dynamic contrast-enhanced MRI (DCE-MRI) using indicator-dilution analysis in complex pulmonary circulation. Since PS offers the pre-capillary perfusion of the first-pass transit, we hypothesized that an inflow-weighted perfusion model of DCE-MRI could simulate the result by PS. METHODS: 22 patients underwent DCE-MRI at 1.5T and also PS. Relative perfusion contributed by the left lung was calculated by PS (PS(L%)), by DCE-MRI using conventional indicator dilution theory for pulmonary blood volume (PBV(L%)) and pulmonary blood flow (PBFL%) and using our proposed inflow-weighted pulmonary blood volume (PBV(iw)(L%)). For PBViw(L%), the optimal upper bound of the inflow-weighted integration range was determined by correlation coefficient analysis. RESULTS: The time-to-peak of the normal lung parenchyma was the optimal upper bound in the inflow-weighted perfusion model. Using PSL% as a reference, PBV(L%) showed error of 49.24% to -40.37% (intraclass correlation coefficient R(I) = 0.55) and PBF(L%) had error of 34.87% to -27.76% (R(I) = 0.80). With the inflow-weighted model, PBV(iw)(L%) had much less error of 12.28% to -11.20% (R(I) = 0.98) from PS(L%). CONCLUSIONS: The inflow-weighted DCE-MRI provides relative perfusion maps similar to that by PS. The discrepancy between conventional indicator-dilution and inflow-weighted analysis represents a mixed-flow component in which pathological flow such as shunting or collaterals might have participated.
所屬典藏
期刊論文引用此條目
Lin, Y.-R., Tsai, S.-Y., Huang, T.-Y., Chung, H.-W., Huang, Y.-L., Wu, F.-Z., Lin, C.-C., Peng, N.-J., & Wu, M.-T. (2013). Inflow-weighted pulmonary perfusion: comparison between dynamic contrast-enhanced MRI versus perfusion scintigraphy in complex pulmonary circulation. Journal of Cardiovascular Magnetic Resonance, 15(1), 21. https://doi.org/10.1186/1532-429x-15-21
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/218012