Abstract: This paper deals with the flux estimation of a permanent-magnet synchronous motor (PMSM). Contrary to the conventional no-load test, the proposed method needs no extra servomotor. It is simply to drive the PMSM in a single-phase mode with the currents large enough to make the PMSM rotate in the same direction. Under such a condition, the flux of the PMSM can be easily estimated. (C) 2004 Elsevier B.V. All rights reserved.