Improvement in wafer temperature uniformity and flow pattern in a lamp heated rapid thermal processor
檔案
- 000088340400024.pdf (542.8 KB, Adobe PDF)
日期
2000-07-01
類型
系所
期刊名稱
JOURNAL OF CRYSTAL GROWTH
卷期與頁次
第 217 卷第 1-2 期,頁 201–210
ISSN
0022-0248
語言
英文
摘要
An experimental lamp heated, rapid thermal processor (RTP) for an 8-in single silicon wafer was designed and established to investigate the thermal and flow characteristics in the processing chamber by transient temperature measurement and flow visualization. Experiments were carried out to explore the effects of placing a highly conducting copper plate right below the wafer on the uniformity of the wafer temperature and effects of the showerhead on the resulting flow distribution in the processing chamber. The measured data indicated that adding the copper plate can effectively reduce the nonuniformity of the wafer temperature. Besides, using a showerhead with finer holes in it results in a better flow distribution in the processor. (C) 2000 Elsevier Science B.V. All rights reserved.
所屬典藏
期刊論文引用此條目
Yin, C., Hsiao, C., & Lin, T. (2000). Improvement in wafer temperature uniformity and flow pattern in a lamp heated rapid thermal processor. JOURNAL OF CRYSTAL GROWTH, 217(1-2), 201–210. https://doi.org/10.1016/S0022-0248(00)00450-4
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/30421