Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | LIN, TF | en_US |
dc.contributor.author | YIN, CP | en_US |
dc.contributor.author | YAN, WM | en_US |
dc.date.accessioned | 2014-12-08T15:05:16Z | - |
dc.date.available | 2014-12-08T15:05:16Z | - |
dc.date.issued | 1991-05-01 | en_US |
dc.identifier.issn | 0022-1481 | en_US |
dc.identifier.uri | http://hdl.handle.net/11536/3806 | - |
dc.description.abstract | Unsteady laminar aiding and opposing mixed convection heat transfer in a vertical flat duct is numerically investigated for an initially fully developed flow. Results indicate that unsteady heat transfer characteristics in the flow are principally determined by wall-to-fluid heat capacity ratios. Effects of the buoyancy and degree of asymmetric heating or cooling are rather insignificant. Correlation equations for the time variations of local Nusselt numbers with wall-to-fluid heat capacity ratios are proposed. | en_US |
dc.language.iso | en_US | en_US |
dc.title | TRANSIENT LAMINAR MIXED CONVECTIVE HEAT-TRANSFER IN A VERTICAL FLAT DUCT | en_US |
dc.type | Article | en_US |
dc.identifier.journal | JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME | en_US |
dc.citation.volume | 113 | en_US |
dc.citation.issue | 2 | en_US |
dc.citation.spage | 384 | en_US |
dc.citation.epage | 390 | en_US |
dc.contributor.department | 機械工程學系 | zh_TW |
dc.contributor.department | Department of Mechanical Engineering | en_US |
dc.identifier.wosnumber | WOS:A1991HP75900016 | - |
dc.citation.woscount | 13 | - |
Appears in Collections: | Articles |