This study employs a simple measurement methodology that is based on the de-convolution of a square test stimulus to measure the transmission characteristics of the human body channel in an electrostatic-coupling intra body communication system. A battery-powered square waveform generator was developed to mimic the electrostatic-coupling intra body communication system operating in the environment of the ground free. The measurement results are then confirmed using a reliable measuring method (single tone) and spectral analysis. The results demonstrate that the proposed measurement approach is valid for up to 32.5 MHz, providing a data rate of over 16 Mbps.

所屬典藏

期刊論文
顯示完整詮釋資料 統計資料

引用此條目

Tseng, Y., Su, C., & Liu, C.-N. J. (2010). Measuring the Transmission Characteristic of the Human Body in an Electrostatic-Coupling Intra Body Communication System Using a Square Test Stimulus. IEICE TRANSACTIONS ON FUNDAMENTALS OF ELECTRONICS COMMUNICATIONS AND COMPUTER SCIENCES, E93A(3), 664–668. https://doi.org/10.1587/transfun.E93.A.664