Measuring the Transmission Characteristic of the Human Body in an Electrostatic-Coupling Intra Body Communication System Using a Square Test Stimulus
檔案
- 000276761000015.pdf (461.3 KB, Adobe PDF)
日期
2010-03-01
類型
系所
期刊名稱
IEICE TRANSACTIONS ON FUNDAMENTALS OF ELECTRONICS COMMUNICATIONS AND COMPUTER SCIENCES
卷期與頁次
第 E93A 卷第 3 期,頁 664–668
ISSN
0916-8508
語言
英文
摘要
This study employs a simple measurement methodology that is based on the de-convolution of a square test stimulus to measure the transmission characteristics of the human body channel in an electrostatic-coupling intra body communication system. A battery-powered square waveform generator was developed to mimic the electrostatic-coupling intra body communication system operating in the environment of the ground free. The measurement results are then confirmed using a reliable measuring method (single tone) and spectral analysis. The results demonstrate that the proposed measurement approach is valid for up to 32.5 MHz, providing a data rate of over 16 Mbps.
所屬典藏
期刊論文引用此條目
Tseng, Y., Su, C., & Liu, C.-N. J. (2010). Measuring the Transmission Characteristic of the Human Body in an Electrostatic-Coupling Intra Body Communication System Using a Square Test Stimulus. IEICE TRANSACTIONS ON FUNDAMENTALS OF ELECTRONICS COMMUNICATIONS AND COMPUTER SCIENCES, E93A(3), 664–668. https://doi.org/10.1587/transfun.E93.A.664
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。