MESOPOROUS CARBON POWDER GAS SENSORS FOR DETECTION OF CARBON MONOXIDE
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
404 | en_US |
dc.citation.issue |
6 | en_US |
dc.citation.spage |
399 | en_US |
dc.citation.volume |
21 | en_US |
dc.citation.woscount |
1 | |
dc.contributor.author |
Lu, Chih-Cheng | en_US |
dc.contributor.author |
Liao, Kuan-Hsun | en_US |
dc.contributor.author |
Tsai, Jeff Tsung-Hui | en_US |
dc.contributor.author |
Liu, Chueh-Yang | en_US |
dc.contributor.author |
Leu, Jih-Perng | en_US |
dc.contributor.department |
材料科學與工程學系 | zh_TW |
dc.contributor.department |
Department of Materials Science and Engineering | en_US |
dc.date.accessioned |
2014-12-08T15:08:09Z | |
dc.date.available |
2014-12-08T15:08:09Z | |
dc.date.issued |
2009-12-01 | en_US |
dc.description.abstract |
This article reports a new class of silicon-based microgas sensors utilizing hexagonally-ordered mesoporous carbon powders (MCPs) as the sensitive film. The mesoporous carbon powders featuring high-specific surface area are replicated by the SBA-15 silica template and immobilized between Cr electrodes on a 9 x 9 cm silicon chip by using a. c. dielectrophoresis (DEP) process at room temperature. The silicon sensor platform comprises Cr microheaters embedded in a dielectric thin membrane manufactured by microelectromechanical systems back-etching techniques. It is shown that MCPs can be satisfactorily aligned along electric fields and accumulated to the electrode area. Investigations into CO detection are carried out to verify gas-sensitive characteristics of the MCP nanofilm. Our experimental results disclose the mesoporous carbon powders are successfully chemoresistive to CO, and demonstrate distinct resistance change with respect to ppm-level variation. In addition, response time, recovery time, and reproducible sensing behavior are experimentally obtained. | en_US |
dc.identifier.doi |
10.4015/S1016237209001684 | en_US |
dc.identifier.issn |
1016-2372 | en_US |
dc.identifier.journal |
BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS | en_US |
dc.identifier.uri |
http://dx.doi.org/10.4015/S1016237209001684 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/6361 | |
dc.identifier.wosnumber |
WOS:000272918500009 | |
dc.language.iso |
en_US | en_US |
dc.subject |
Mesoporous carbon powder | en_US |
dc.subject |
Dielectrophoresis | en_US |
dc.subject |
Microhotplate | en_US |
dc.subject |
MEMS | en_US |
dc.subject |
Gas sensor | en_US |
dc.title |
MESOPOROUS CARBON POWDER GAS SENSORS FOR DETECTION OF CARBON MONOXIDE | en_US |
dc.type |
Article | en_US |
檔案
本條目沒有附加檔案。
所屬典藏: 期刊論文
引用此條目
Lu, C.-C., Liao, K.-H., Tsai, J. T.-H., Liu, C.-Y., & Leu, J.-P. (2009). MESOPOROUS CARBON POWDER GAS SENSORS FOR DETECTION OF CARBON MONOXIDE. BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 21(6), 399–404. https://doi.org/10.4015/S1016237209001684
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/6361