Coagulation monitoring in surface water treatment facilities

檔案

本條目沒有附加檔案。

日期

1998

期刊名稱

WATER SCIENCE AND TECHNOLOGY

摘要

Coagulant dosing is traditionally determined according to results from jar-tests or operator's experience, which often lead to overdosing or-insufficient dosing. In this study, the feasibility of applying an optical monitoring technique to determine chemical dosage and to monitor the coagulation performance in water treatment plants were assessed. To examine the applicability of the monitor under various operation conditions, series of batch trials in the field were conducted to explore the effects of turbidity, pH and rapid mixing intensity on the effectiveness of coagulation. The performance was directly reflected in the output ratio of the monitor, which proved to be an effective index for the flee size and its settling velocity. Therefore, we consider that the optical monitor is an useful instrument in monitoring coagulation in water treatment. (C) 1998 Published by Elsevier Science Ltd. All rights reserved.

所屬典藏

會議論文
顯示完整詮釋資料 統計資料

引用此條目

Kan, C., & Huang, C. (1998). Coagulation monitoring in surface water treatment facilities. WATER SCIENCE AND TECHNOLOGY, 38(3), 237–244. https://doi.org/10.1016/S0273-1223(98)00465-X

BibTeX RIS

引用文字依 APA 第 7 版格式自動產生,使用前請再核對。

分享

永久網址:https://ir.lib.nycu.edu.tw/handle/11536/65