標題: | Degradation of carbofuran-contaminated water by the Fenton process |
作者: | Ma, Ying-Shih Kumar, Mathava Lin, Jih-Gaw 環境工程研究所 Institute of Environmental Engineering |
關鍵字: | Carbofuran;Fenton process;central composite design (CCD);intermediates;degradation pathway |
公開日期: | 15-七月-2009 |
摘要: | In this study, the Fenton process was applied for the degradation of carbofuran from aqueous system. Batch experiments were conducted at two different carbofuran concentrations i.e., 10 and 50 mg/L, and at pH 3. Batch experiments at each carbofuran concentration were designed by central composite design (CCD) with two independent variables i.e. Fe(2+) and H(2)O(2). Experimental results indicate that more than 90% of carbofuran removal was observed within 5 mins of Fenton reaction at 5 mg/L of Fe(2+) concentration and 100 mg/L of H(2)O(2) concentration. Increases in Fe(2+) and/or H(2)O(2) concentrations beyond 5 and 100 mg/L, respectively produced 100% carbofuran removal. Based on the experimental observations, the optimal Fe(2+) and H(2)O(2) dosages required for 10 mg/L of aqueous carbofuran removal were estimated as 7.4 and 143 mg/L, respectively. During this study, three carbofuran intermediates such as 7-benzofuranol,2,3,-dihydro-2,2-dimethyl, 7-hydroxy-2,2-dimethyl-benzofuran-3-one and 1,4-Benzene-di- carboxaldehyde were identified using GC/MS analyses. |
URI: | http://dx.doi.org/10.1080/10934520902958807 http://hdl.handle.net/11536/6952 |
ISSN: | 1093-4529 |
DOI: | 10.1080/10934520902958807 |
期刊: | JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING |
Volume: | 44 |
Issue: | 9 |
起始頁: | 914 |
結束頁: | 920 |
顯示於類別: | 期刊論文 |