An on-line pulse trains analysis system of the wire-EDM process

檔案

日期

2009-05-01

類型

期刊名稱

JOURNAL OF MATERIALS PROCESSING TECHNOLOGY

卷期與頁次

第 209 卷第 9 期,頁 4417–4422

ISSN

0924-0136

語言

英文

摘要

Ignition delay time (Td) has been widely used to distinguish the abnormal discharges from the normal ones in wire electrical discharge machining (WEDM) process. In this paper an on-line analysis system for the causality of the Td data sequences was developed to evaluate the machining performance of WEDM process. The system is composed of a stand-alone Td processing circuitry and a user-friendly computer program for data analysis. The Td processing circuitry calculates and records the Td of every single electrical discharge in the first place, and then transmits the Td data via an embedded communication port to a desktop or notebook computer. The computer program, after performing the analysis tasks, will display the result in a graphic way. Two mathematical algorithms were employed for the analysis: autocorrelation function and Fourier transform. Through experiments under different working conditions, it was found that the autocorrelation function could be used to detect if arc or short circuit discharges take place consecutively, and to distinguish the WEDM process with similar Td distributions. On the other hand, the spectral analysis revealed that several factors were identified to be able to induce certain periodic patterns of Td data. These factors include the length of wire electrode, the water pressure, etc. (C) 2008 Elsevier B.V. All rights reserved.

所屬典藏

期刊論文
顯示完整詮釋資料 統計資料

引用此條目

Liao, Y. S., Cheng, M. P., & Liao, K. W. (2009). An on-line pulse trains analysis system of the wire-EDM process. JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 209(9), 4417–4422. https://doi.org/10.1016/j.jmatprotec.2008.10.015

BibTeX RIS

引用文字依 APA 第 7 版格式自動產生,使用前請再核對。

分享

永久網址:https://ir.lib.nycu.edu.tw/handle/11536/7300