Title: Identifying groundwater pumping source information using simulated annealing
Authors: Lin, Yu-Chung
Yeh, Hund-Der
環境工程研究所
Institute of Environmental Engineering
Keywords: groundwater;inverse problem;heuristic approach;pumping source identification;simulated annealing
Issue Date: 30-Jul-2008
Abstract: This study develops an approach referred to as SA-MF using simulated annealing (SA) and a three-dimensional groundwater flow model (MODFLOW-2000) to determine the pumping source information, namely the pumping source location, the pumping rate and the pumping period. Eight scenarios, each with various cases for aquifers with homogeneous or heterogeneous conductivities, are used to test the applicability and accuracy of SA-MF in determining the pumping source information. The results show that at least five measured heads should be used to analyse the pumping source identification problem and at least three observation wells are required to effectively determine the pumping source information. The SA-MF gives good estimated results in both synthetic and real problems even if the measured heads contain measurement errors. Copyright (C) 2008 John Wiley & Sons, Ltd.
URI: http://dx.doi.org/10.1002/hyp.6875
http://hdl.handle.net/11536/8552
ISSN: 0885-6087
DOI: 10.1002/hyp.6875
Journal: HYDROLOGICAL PROCESSES
Volume: 22
Issue: 16
Begin Page: 3010
End Page: 3019
Appears in Collections:Articles


Files in This Item:

  1. 000258244500011.pdf

If it is a zip file, please download the file and unzip it, then open index.html in a browser to view the full text content.