A numerical investigation of the geometric effects on the performance of plate finned-tube heat exchanger
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.citation.epage |
1643 | en_US |
dc.citation.issue |
3 | en_US |
dc.citation.spage |
1638 | en_US |
dc.citation.volume |
52 | en_US |
dc.citation.woscount |
10 | |
dc.contributor.author |
Lu, Chi-Wen | en_US |
dc.contributor.author |
Huang, Jeng-Min | en_US |
dc.contributor.author |
Nien, W. C. | en_US |
dc.contributor.author |
Wang, Chi-Chuan | en_US |
dc.contributor.department |
機械工程學系 | zh_TW |
dc.contributor.department |
Department of Mechanical Engineering | en_US |
dc.date.accessioned |
2014-12-08T15:12:02Z | |
dc.date.available |
2014-12-08T15:12:02Z | |
dc.date.issued |
2011-03-01 | en_US |
dc.description.abstract |
This study numerically examines the geometric parameters on the performance of a two-row fin-and-tube heat exchanger. Effects of fin pitch, tube pitch, fin thickness, and tube diameter are termed with. The simulation indicates that the performance, in terms of Q/Delta P and COP, increases with longitudinal tube pitch or with transverse tube pitch, and it decreases with larger tube diameter or fin thickness. An optimum value for Q/Delta P occurs at a 6-8 fpi at a fixed flow rate condition. There is not much difference in choosing the index of Q/Delta P or COP under fixed flow rate condition. However, when the simulation are performed with the actual axial fan whose P-Q curve being implemented. It is found that Q/Delta P peaks at 12 fpi while COP peaks at 16 fpi. (C) 2010 Elsevier Ltd. All rights reserved. | en_US |
dc.identifier.doi |
10.1016/j.enconman.2010.10.026 | en_US |
dc.identifier.issn |
0196-8904 | en_US |
dc.identifier.journal |
ENERGY CONVERSION AND MANAGEMENT | en_US |
dc.identifier.uri |
http://dx.doi.org/10.1016/j.enconman.2010.10.026 | en_US |
dc.identifier.uri |
https://ir.lib.nycu.edu.tw/handle/11536/9217 | |
dc.identifier.wosnumber |
WOS:000287071000009 | |
dc.language.iso |
en_US | en_US |
dc.subject |
Fin-and-tube heat exchanger | en_US |
dc.subject |
Axial fan | en_US |
dc.subject |
CFD | en_US |
dc.title |
A numerical investigation of the geometric effects on the performance of plate finned-tube heat exchanger | en_US |
dc.type |
Article | en_US |
檔案
- 000287071000009.pdf (743.6 KB, Adobe PDF)
所屬典藏: 期刊論文
引用此條目
Lu, C.-W., Huang, J.-M., Nien, W. C., & Wang, C.-C. (2011). A numerical investigation of the geometric effects on the performance of plate finned-tube heat exchanger. ENERGY CONVERSION AND MANAGEMENT, 52(3), 1638–1643. https://doi.org/10.1016/j.enconman.2010.10.026
引用文字依 APA 第 7 版格式自動產生,使用前請再核對。
分享
永久網址:https://ir.lib.nycu.edu.tw/handle/11536/9217