Seismic self-centering steel beam-to-column moment connections using bolted friction devices

檔案

日期

2008-04-10

類型

期刊名稱

EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS

卷期與頁次

第 37 卷第 4 期,頁 627–645

ISSN

0098-8847

語言

英文

摘要

This paper first presents the force-deformation relationship of a post-tensioned (PT) steel beam-to-column connection constructed with bolted web friction devices (FDs). This paper then describes the test program conducted in the National Center for Research on Earthquake Engineering, Taiwan, on four bolted FDs and four full-scale PT beam-to-column moment connection subassemblies using the FDs. Tests confirm that (1) the hysteretic behavior of four bolted FDs is very stable, (2) the friction coefficient between the steel plate and the brass shim is about 0.34, (3) the proposed force-deformation relationships reasonably predict the experimental responses of the PT connections under cyclically increasing deformations up to a beam peak rotation of 0.05 rad, and (4) the decompression moments do not degrade as beam cyclic deformations increase. Copyright (C) 2007 John Wiley & Sons, Ltd.

所屬典藏

期刊論文
顯示完整詮釋資料 統計資料

引用此條目

Tsai, K.-C., Chou, C.-C., Lin, C.-L., Chen, P.-C., & Jhang, S.-J. (2008). Seismic self-centering steel beam-to-column moment connections using bolted friction devices. EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 37(4), 627–645. https://doi.org/10.1002/eqe.779

BibTeX RIS

引用文字依 APA 第 7 版格式自動產生,使用前請再核對。

分享

永久網址:https://ir.lib.nycu.edu.tw/handle/11536/9462