Browsing by Author "Aggarwal, SG"
Now showing 1 - 6 of 6
- Results Per Page
- Sort Options
Item type:Item, Concentration profiles of acidic and basic air pollutants around an industrial park of Taiwan(2004-01-01) ;Tsai, CJ ;Aggarwal, SG ;Chang, CT ;Hung, IF環境工程研究所The results of spatial and temporal distribution of acidic and basic air pollutants in ambient air around Hsinchu Science-Based Industrial Park (SBIP), Taiwan during August 2000 to October 2001 are presented. The sampling was performed on 13 different sites around the SBIP for 12 hrs each every month, and a total of 195 samples were collected. The effect of geographical and meteorological conditions, and production volume of the SBIP on the variation of pollutant's concentration was investigated. The spatial distribution shows that comparatively higher concentration of pollutants was found on the sites, which are either low in altitude such as the WS (west-southern) part of SBIP, in the downwind location or close to the factories. In case the wind velocity was low, i.e. below 2 m s(-1), the concentration of pollutant tended to increase and became uniformly distributed around the science park. The temporal distribution shows a decrease in ambient concentration of pollutants from February to June 2001, mainly due to the decline in the production volume of the SBIP in this period. During the whole period of investigation, the concentration of most of the species ( except HF) was found to be lower than the factory-surrounding air quality standard of Taiwan, but in some cases it was higher than the AALG.Item type:Item, Inorganic acid emission factors of semiconductor manufacturing processes(2004-02-01) ;Chein, HM ;Chen, TM ;Aggarwal, SG ;Tsai, CJHuang, CCA huge amount of inorganic acids can be produced and emitted with waste gases from integrated circuit manufacturing processes such as cleaning and etching. Emission of inorganic acids from selected semiconductor factories was measured in this study. The sampling of the inorganic acids was based on the porous metal denuders, and samples were then analyzed by ion chromatography. The amount of chemical usage was adopted from the data that were reported to the Environmental Protection Bureau in Hsin-chu County according to the Taiwan Environmental Protection Agency regulation. The emission factor is defined as the emission rate (kg/month) divided by the amount of chemical usage (L/month). Emission factors of three inorganic acids (i.e., hydrofluoric acid [HF], hydrochloric acid [HCl], and sulfuric acid [H2SO4]) were estimated by the same method. The emission factors of HF and HCl were determined to be 0.0075 kg/L (coefficient of variation [CV] = 60.7%, n = 80) and 0.0096 kg/L (CV = 68.2%, n = 91), respectively. Linear regression equations are proposed to fit the data with correlation coefficient square (R-2) = 0.82 and 0.9, respectively. The emission factor of H2SO4, which is in the droplet form, was determined to be 0.0016 kg/L (CV = 99.2%, n = 107), and its R-2 was 0.84. The emission profiles of gaseous inorganic acids show that HF is the dominant chemical in most of the fabricators.Item type:Item, Simultaneous sampling of gas- and aerosol-phase TDI with a triple filter system(2003-10-01) ;Tsai, CJ ;Cheng, KC ;Aggarwal, SG ;Shih, TSHung, IFA new triple filter system sampler/model is proposed for the precise and accurate simultaneous sampling and determination of gas- and aerosol-phase 2,4-toluene diisocyanate (TDI). The system consists of two front Teflon filters for sampling aerosol-phase TDI and a final coated glass fiber filter to collect gas-phase TDI. The aerosol-phase TDI is collected on the first Teflon filter, while the second Teflon filter is used to estimate gaseous TDI adsorbed by the first. According to the gas adsorption test of two Teflon filters in series, the TDI gas adsorption fraction of the two filters is almost the same. Results of the evaporation test using pure TDI aerosols collected on the Teflon filter show that significant evaporation of the compound does not occur during sampling. These two findings allow the use of a model to estimate accurate gas- and aerosol-phase TDI, concentrations. The comparison test with an annular denuder shows that the triple filter system can minimize the TDI sampling bias between the dual filter and the annular denuder systems.Item type:Item, Speciation of arsenic in environmental and biological samples(2002-08-01) ;Aggarwal, SG ;Diwan, BD ;Agarwal, S ;Gupta, VKMundhara, LA novel arsine generator glass assembly is constructed and reported for the spectrophotometric determination and speciation of arsenic in real samples. In an arsine generator, sodium borohydride is added dropwise to the acidic sample solution and arsine thus formed is reacted with silver diethyldithiocarbamate (Ag-DDTC) - Tritron-X (TX-100) solution in pyridine to form a red coloured complex. The complex showed the absorption maximum at lambda(max) 540 nm. The molar absorptivity of the method was found to be (1.5.5) x 10(4) L mole(-1) cm(-1) at this wavelength. The presence of non-ionic surfactant, i.e. TX-100 in the Ag-DDTC solution, makes the method = 3 times more sensitive than the conventional Ag-DDTC method. Beer's law is obeyed in the concentration range of 0.05-2.80 mg L-1 of arsenic. The detection limit of the method was calculated to be 20 mug L-1 As. Speciation of arsenite from other forms of arsenic in sample solutions was carried out by extraction of arsenite with Pb-DDTC in chloroform, followed by spectrophotometric determination. After arsenite separation the sample is used for the arsenate determination. Total arsenic was determined by acid decomposition of the same sample. The speciation data were found to be comparable (2%) with ICP-MS, with better precision (< 1%). The method has been successfully applied for the speciation of arsenic in drinking water and dust samples of arsenic affecting the Rajnandgaon district of Chhattisgarh, India, and urine and blood samples of patients with arsenical diseases. Concentration of total arsenic in tube-well water of this area was 3-6 times more than the permissible limit. Dust samples contained less amounts of arsenic than the ground water.Item type:Item, The effect of environmental conditions and electrical charge on the weighing accuracy of different filter materials(2002-07-03) ;Tsai, CJ ;Chang, CT ;Shih, BH ;Aggarwal, SGLi, SNDifferent filter materials and electrical charge elimination methods were used to investigate the weighing accuracy of filter papers under different environmental conditions. The results show that the standard deviations (S.D.) of weight data for glass fiber and MCE filters were substantial without environmental control, whether or not the electrical charge eliminators were used. Values of 0.157 and 0.349 mg were determined for glass and NICE filters, respectively. The accuracy of weighing was substantially improved and the S.D. was reduced to 0.01 and 0.09 mg for glass fiber and MCE filters, respectively, after applying the environmental control conditions. For PVC and Teflon filters, the accuracy of weighing was good, even in the uncontrolled environmental conditions, whether or not the electrical charge eliminators were used. The S.D. values of weighing data of PVC and Teflon filters were 0.007 and 0.011 mg, respectively. (C) 2002 Elsevier Science B.V. All rights reserved.Item type:Item, Thermophoretic deposition of particles in laminar and turbulent tube flows(2004-02-01) ;Tsai, CJ ;Lin, JS ;Aggarwal, SG ;Chen, DR環境工程研究所Thermophoretic deposition of aerosol particles (particle diameter ranges from 0.038 to 0.498 mum) was measured in a tube (1.18 m long, 0.43 cm inner diameter, stainless steel tube) using monodisperse NaCl test particles under laminar and turbulent flow conditions. In the previous study by Romay et al., theoretical thermophoretic deposition efficiencies in turbulent flow regime do not agree well with the experimental data. In this study, particle deposition efficiencies due to other deposition mechanisms such as electrostatic deposition for particles in Boltzmann charge equilibrium and laminar and turbulent diffusions were carefully assessed so that the deposition due to thermophoresis alone could be measured accurately. As a result, the semiempirical equation developed by Lin and Tsai in laminar flow regime and the theoretical equation of Romay et al. in turbulent flow regime are found to fit the experimental data of thermophoretic deposition efficiency very well with the differences of less than 1.0% in both flow regimes. It is also found that Talbot's formula for the thermophoretic coefficient is accurate while Waldmann's free molecular formula is only applicable when Kn is greater than about 3.0.