Browsing by Author "Banerjee, Ansuman"
Now showing 1 - 3 of 3
- Results Per Page
- Sort Options
Item type:Item, Flexible Droplet Routing in Active Matrix-Based Digital Microfluidic Biochips(2018-04-01) ;Lu, Guan-Ruei ;Kuo, Chun-Hao ;Chiang, Kuen-Cheng ;Banerjee, AnsumanBhattacharya, Bhargab B.The active matrix (AM)-based architecture offers many advantages over conventional digital electrowetting-on-dielectric (EWOD) microfluidic biochips, such as the capability of handling variable-size droplets, more flexible droplet movement, and precise control over droplet navigation. However, a major challenge in choosing the routing paths is to decide when the droplets are to be reshaped depending on the congestion of the intended path, or split- and route sub droplets,and merging them at their respective destinations. As the number of microelectrodes in AM-EWOD chips is large, the path selection problem becomes further complicated. In this article, we propose a negotiation-guided flow based on routing of subdroplets that obviates the explicit need for deciding when the droplets are to be manipulated, yet fully utilizing the power of droplet reshaping, splitting, and merging them to facilitate their journey. The proposed algorithm reduces routing cost and provides more freedom in deadlock avoidance in the presence of multiple routing tasks by assigning certain congestion penalty for sibling subdroplets and fluidic penalty for heterogeneous droplets. Compared to existing techniques, it reduces latest arrival time by an average of 29% for several benchmark and random test suites. Furthermore, our method is observed to provide 100% routability of nets for all test cases, whereas existing and baseline routers fail to produce feasible solutions in many instances. We also propose a reliable mode droplet routing strategy where the number of unreliable splitting operations can be reduced by paying a small penalty on latest arrival time.Item type:Item, On Reliability Hardening in Cyber-Physical Digital-Microfluidic Biochips(2017-01-01) ;Lu, Guan-Ruei ;Huang, Guan-Ming ;Banerjee, Ansuman ;Bhattacharya, Bhargab B.Ho, Tsung-YiIn the area of biomedical engineering, digital-microfluidic biochips (DMFBs) have received considerable attention, because of their capability of providing an efficient and reliable platform for conducting point-of-care clinical diagnostics. System reliability, in turn, mandates error-recoverability while implementing biochemical assays on-chip for medical applications. Unfortunately, the technology of DMFBs is not yet fully equipped to handle error-recovery from various microfluidic operations involving droplet motion and reaction. Recently, a number of cyber-physical systems have been proposed to provide real-time checking and error-recovery in assays based on the feedback received from a few on-chip checkpoints. However, in order to synthesize robust feedback systems for different types of DMFBs, certain practical issues need to be considered such as co-optimization of checkpoint placement and layout of droplet-routing pathways. For application-specific DMFBs, we propose here an algorithm that minimizes the number of checkpoints and determines their locations to cover every path in a given droplet-routing solution. Next, for general-purpose DMFBs, where the checkpoints are pre-deployed in specific locations, we present a checkpoint-aware routing algorithm such that every droplet-routing path passes through at least one checkpoint to enable error-recovery and to ensure physical routability of all droplets. Our experiments on assay benchmarks show encouraging results in terms of latest-arrival-time and routability of droplets. The proposed methods thus provide convenient reliability-hardening mechanisms for a wide class of cyber-physical DMFBs.Item type:Item, Reliability Hardening Mechanisms in Cyber-Physical Digital-Microfluidic Biochips(2018-10-01) ;Lu, Guan-Ruei ;Banerjee, Ansuman ;Bhattacharya, Bhargab B. ;Ho, Tsung-YiChen, Hung-MingIn the area of biomedical engineering, digital-microfluidic biochips (DMFBs) have received considerable attention because of their capability of providing an efficient and reliable platform for conducting point-of-care clinical diagnostics. System reliability, in turn, mandates error-recoverability while implementing biochemical assays on-chip for medical applications. Unfortunately, the technology of DMFBs is not yet fully equipped to handle error-recovery from various microfluidic operations involving droplet motion and reaction. Recently, a number of cyber-physical systems have been proposed to provide real-time checking and error-recovery in assays based on the feedback received from a few on-chip checkpoints. However, to synthesize robust feedback systems for different types of DMFBs, certain practical issues need to be considered such as co-optimization of checkpoint placement, error-recoverability, and layout of droplet-routing pathways. For application-specific DMFBs, we propose here an algorithm that minimizes the number of checkpoints and determines their locations to cover every path in a given droplet-routing solution. Next, for general-purpose DMFBs, where the checkpoints are pre-deployed in specific locations, we present a checkpoint-aware routing algorithm such that every droplet-routing path passes through at least one checkpoint to enable error-recovery and to ensure physical routability of all droplets. Furthermore, we also propose strategies for executing the algorithms in reliable mode to enhance error-recoverability. The proposed methods thus provide reliability-hardening mechanisms for a wide class of cyber-physical DMFBs.