Browsing by Author "Chang, Chen-Wei"
Now showing 1 - 2 of 2
- Results Per Page
- Sort Options
Item type:Item, A NOVEL ELECTROMAGNETIC TARGETING SYSTEM USING ROTATING MAGNETIC-FLUX CONCENTRATION METHOD FOR NAVIGATING ENDOBRONCHOSCOPY(2018-01-01) ;Chen, Chin-Chung ;Lin, Ching-Kai ;Cheng, Yun-Chien ;Chang, Chen-WeiTsai, Sung-LinIn this paper, we proposed a novel electromagnetic targeting system using rotating magnetic-flux concentration method for navigating endo-bronchoscope. This system consists of a magnetic-flux emitting coil, a magnetic-flux receiving electromagnets-array, a 2D model of bronchial tree, the magnetic-flux concentrator embedded on brush-guiding tube which was connected to the guide sheath. When the concentrator in the 2D bronchial tree passes through the air gap between the emitting coil and the receiving electromagnets array, the concentrator concentrates the magnetic flux between the coil and the array. The concentrated magnetic flux is subsequently received by the receiving electromagnets-array and thus stable voltage output is produced. Furthermore, when the concentrator is rotated, the concentration of the magnetic flux is periodically changed and thereby the voltage output is periodically changed. By analyzing the voltage changes, the location of the concentrator (as well as guide tube and sheath) is targeted. According to the experimental results, the system successfully targets the location of the guide sheath in the 2D model of bronchial tree.Item type:Item, Passive Magnetic-Flux-Concentrator Based Electromagnetic Targeting System for Endobronchoscopy(2019-12-01) ;Chen, Chin-Chung ;Lin, Ching-Kai ;Chang, Chen-Wei ;Cheng, Yun-ChienChen, Jia-EnIn this paper, we demonstrate an innovative electromagnetic targeting system utilizing a passive magnetic-flux-concentrator for tracking endobronchoscope used in the diagnosis process of lung cancer tumors/lesions. The system consists of a magnetic-flux emitting coil, a magnetic-flux receiving electromagnets-array, and high permeability silicon-steel sheets rolled as a collar (as the passive magnetic-flux-concentrator) fixed in a guide sheath of an endobronchoscope. The emitting coil is used to produce AC magnetic-flux, which is consequently received by the receiving electromagnets-array. Due to the electromagnetic-induction, a voltage is induced in the receiving electromagnets-array. When the endobronchoscope's guide sheath (with the silicon-steel collar) travels between the emitting coil and the receiving electromagnets-arrays, the magnetic flux is concentrated by the silicon-steel collar and thereby the induced voltage is changed. Through analyzing the voltage-pattern change, the location of the silicon-steel collar with the guide sheath is targeted. For testing, a bronchial-tree model for training medical doctors and operators is used to test our system. According to experimental results, the system is successfully verified to be able to target the endobronchoscope in the bronchial-tree model. The targeting errors on the x-, y- and z-axes are 9 mm, 10 mm, and 5 mm, respectively.