Browsing by Author "Chang, Chia-Lin"
Now showing 1 - 4 of 4
- Results Per Page
- Sort Options
Item type:Item, A Fully Integrated Nose-on-a-Chip for Rapid Diagnosis of Ventilator-Associated Pneumonia(2014-12-01) ;Chiu, Shih-Wen ;Wang, Jen-Huo ;Chang, Kwuang-Han ;Chang, Ting-HauWang, Chia-MinVentilator-associated pneumonia (VAP) still lacks a rapid diagnostic strategy. This study proposes installing a nose-on-a-chip at the proximal end of an expiratory circuit of a ventilator to monitor and to detect metabolite of pneumonia in the early stage. The nose-on-a-chip was designed and fabricated in a 90-nm 1P9M CMOS technology in order to downsize the gas detection system. The chip has eight on-chip sensors, an adaptive interface, a successive approximation analog-to-digital converter (SAR ADC), a learning kernel of continuous restricted Boltzmann machine (CRBM), and a RISC-core with low-voltage SRAM. The functionality of VAP identification was verified using clinical data. In total, 76 samples infected with pneumonia (19 Klebsiella, 25 Pseudomonas aeruginosa, 16 Staphylococcus aureus, and 16 Candida) and 41 uninfected samples were collected as the experimental group and the control group, respectively. The results revealed a very high VAP identification rate at 94.06% for identifying healthy and infected patients. A 100% accuracy to identify the microorganisms of Klebsiella, Pseudomonas aeruginosa, Staphylococcus aureus, and Candida from VAP infected patients was achieved. This chip only consumes 1.27 mW at a 0.5 V supply voltage. This work provides a promising solution for the long-term unresolved rapid VAP diagnostic problem.Item type:Item, A Low-Power Bio-Potential Acquisition System with Flexible PDMS Dry Electrodes for Portable Ubiquitous Healthcare Applications(2013-03-01) ;Chen, Chih-Yuan ;Chang, Chia-Lin ;Chang, Chih-Wei ;Lai, Shin-ChiChien, Tsung-FuThis work describes a bio-potential acquisition system for portable ubiquitous healthcare applications using flexible polydimethylsiloxane dry electrodes (FPDEs) and a low-power recording circuit. This novel FPDE used Au as the skin contact layer, which was made using a CO2 laser and replica method technology. The FPDE was revised from a commercial bio-potential electrode with a conductive snap using dry electrodes rather than wet electrodes that proposed reliable and robust attachment for the purpose of measurement, and attaching velcro made it wearable on the forearm for bio-potential applications. Furthermore, this study proposes a recording device to store bio-potential signal data and provides portability and low-power consumption for the proposed acquisition system. To acquire differential bio-potentials, such as electrocardiogram (ECG) signals, the proposed recording device includes a low-power front-end acquisition chip fabricated using a complementary metal-oxide-semiconductor (CMOS) process, a commercial microcontroller (MSP430F149), and a secure digital (SD) card for portable healthcare applications. The proposed system can obtain ECG signals efficiently and are comfortable to the skin. The power consumption of the system is about 85 mW for continuous working over a 3 day period with two AA batteries. It can also be used as a compact Holter ECG system.Item type:Item, A Power-Efficient Bio-Potential Acquisition Device with DS-MDE Sensors for Long-Term Healthcare Monitoring Applications(2010-05-01) ;Chang, Chia-Lin ;Chang, Chih-Wei ;Huang, Hong-Yi ;Hsu, Chen-MingHuang, Chia-HsuanThis work describes a power-efficient bio-potential acquisition device for long-term healthcare applications that is implemented using novel microelectromechanical dry electrodes (MDE) and a low power bio-potential processing chip. Using micromachining technology, an attempt is also made to enhance the sensing reliability and stability by fabricating a diamond-shaped MDE (DS-MDE) that has a satisfactory self-stability capability and superior electric conductivity when attached onto skin without any extra skin tissue injury technology. To acquire differential bio-potentials such as ECG signals, the proposed processing chip fabricated in a standard CMOS process has a high common mode rejection ratio (C. M. R. R.) differential amplifier and a 12-bit analog-to-digital converter (ADC). Use of the proposed system and integrate simple peripheral commercial devices can obtain the ECG signal efficiently without additional skin tissue injury and ensure continuous monitoring more than 70 hours with a 400 mAh battery.Item type:Item, Power-efficient wireless sensor for physiological signal acquisition(2009-04-01) ;Chang, Chia-Lin ;Chang, Chih-Wei ;Hsu, Chen-Ming ;Luo, Ching-HsingChiou, Jin-ChernThis work presents a power-efficient wireless sensor implemented using microelectromechanical system (MEMS)-based dry electrodes (MDE) and a ZigBee protocol chip for physiological signal acquisition. To improve signal quality with low electrode-skin interface impedance, a silicon-based MDE is fabricated via micromachining technology. The proposed wireless sensor can provide four different channels for up to 10 kHz bandwidth, 10-bit resolution biomedical signal transmissions. Different from other systems, the proposed wireless sensor employs a novel power management method for physiological signals to reduce power consumption. The proposed wireless sensor successfully transmits electrocardiogram (ECG) signals and four-channel electroencephalogram (EEG) signals with power consumptions of 92.7 and 56.8 mW respectively. It consumes 46% less power than the original sensor without power management (173 mW) in ECG acquisition and 67% less power in EEG acquisition. The circuit printed-circuit-band area in the proposed wireless sensor is 3.5 x 4.5 cm, suitable for various portable biomedical applications. (C) 2009 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.3124190]