Browsing by Author "Chang, Szu-Chung"
Now showing 1 - 3 of 3
- Results Per Page
- Sort Options
Item type:Item, Application of micro-bubbles on oral care(2017-01-01) ;Lin, Pei-Ju ;Chuang, Ming-Chuen ;Chang, Szu-Chung ;應用藝術研究所Institute of Applied ArtsOBJECTIVE: This study proposed a method of using a modified micro-bubble generator with its ejection nozzle connected to an ergonomically designed soft teeth-tray for plaque removal. The applicability of this method was verified and the influence on plaque removal efficacy of some parameters of this device was clarified. METHODS: The micro-bubble generator used in this study has 5 rotation speed settings, 5 nozzle sizes, and a soft teeth-tray ejection pore diameters. These were used as independent variables to investigate their effect on the ejected flow volume, velocity and micro-bubble dimension, and how they eventually affect the plaque removal efficacy from a denture. RESULTS: When the micro-bubble generator coupled with large (4.8 mm) ejection pore teeth-tray and the largest (1.2 mm) nozzle diameter more than 98% of plaque can be removed; its applicability on cleaning denture can be verified. In general, the larger nozzle diameter and teeth-tray ejection pore diameter will remove more plaques; while the higher the flow velocity and the smaller the micro-bubble of the ejected stream, better cleaning efficacy can be achieved. CONCLUSION: The application of micro-bubble on plaque removal seems effective, although at this moment it is applied on denture cleaning. The finding of the influence of some critical design parameters of micro-bubble generator and variables of ejected stream can be referred to further design a new micro-bubble cleaner for effective plaque removal from the teeth in human oral cavity.Item type:Item, Efficacy of using oxygen microbubble device for facultative anaerobe removal(2018-10-01) ;Lin, Pei-Ju ;Chuang, Ming-Chuen ;Chang, Szu-Chung ;交大名義發表National Chiao Tung UniversityPatients with serious gingivitis or periodontal diseases suffer from receding gums. Brushing teeth with a toothbrush may result in bleeding gums and new wounds, which increases the difficulty of removing facultative anaerobes from gum pockets, to decrease the damage inflicted on gums, this study proposed a cleaning device that can generate and emit oxygen microbubbles for eliminating facultative anaerobes in the mouth cavity. In this study, the authors conducted simulations with a denture to investigate the efficacy of using this method to remove facultative anaerobes. In this research for the optimal device design, several variables were manipulated including rotation speeds of the bubble generator, different nozzle diameters, and different numbers of nozzle holes. The results revealed that the device is effective in removing facultative anaerobes; moreover, of all design variables, the number of nozzle holes was the factor having the largest effect on anaerobe removal, as it influenced the flow volume and oxygen content of the discharge: the greater the number of nozzles, the greater the flow volume, oxygen content, and efficacy of anaerobe removal.Item type:Item, Research on the cleaning efficacy of micro-bubbles on dental plaque(2015-01-01) ;Lin, Pei-Ju ;Chuang, Ming-Chuen ;Chang, Szu-Chung ;應用藝術研究所Institute of Applied ArtsLong-term bed-ridden patients do not usually have the same opportunity for proper dental hygiene as normal individuals, as they often have difficulty using toothbrushes to clean their teeth. Patients with periodontal disease are also at risk of increased bacterial infection due to the propensity for teeth brushing causing bleeding of the gums. Therefore, an alternative method of dental hygiene maintenance is required for these individuals. Our study proposed a method to clean dental plaque through a tooth tray with micro-bubbles and verified its cleaning efficacy through experiment. A cleaning device that produces micro bubbles (Braun MD20) was used in the study with five separately modified nozzle diameters as the independent variable: 0.16mm, 0.30mm, 0.63mm, 0.8mm and 1.2mm. The five different rotation speed settings of the device act as the other independent variable, with the resulting flow volume, velocity and the diameter of the micro-bubbles as the intermediate variables. The effects of these variables on cleaning dental plaque were investigated. Our results showed that an average of 45%similar to 75% cleaning rate of dental plaque was achieved under all combinations of the variables. The best dental plaque removal variable combination was nozzle diameter 0.8mm with speed of 3527 rpm, in which 98% dental plaque removal was achieved. The dimension of the nozzle exerted greater influence on flow volume, flow velocity and bubble diameter than rotation speed. The effect of the control variables on plaque removal was also more significant than intermediate variables, with the nozzle dimension influencing plaque removal at 0.05 significance level. (C) 2015 The Authors. Published by Elsevier B.V.