Browsing by Author "Chen, Chun-Wan"
Now showing 1 - 5 of 5
- Results Per Page
- Sort Options
Item type:Item, Characteristic of nanoparticles generated from different nano-powders by using different dispersion methods(2012-04-01) ;Tsai, Chuen-Jinn ;Lin, Guan-Yu ;Liu, Chun-Nan ;He, Chi-EnChen, Chun-WanA standard rotating drum with a modified sampling train (RD), a vortex shaker (VS), and a SSPD (small-scale powder disperser) were used to investigate the emission characteristics of nano-powders, including nano-titanium dioxide (nano-TiO2, primary diameter: 21 nm), nano-zinc oxide (nano-ZnO, primary diameter: 30-50 nm), and nano-silicon dioxide (nano-SiO2, primary diameter: 10-30 nm). A TSI SMPS (scanning mobility particle sizer), a TSI APS (aerodynamic particle sizer), and a MSP MOUDI (micro-orifice uniform deposit impactor) were used to measure the number and mass distributions of generated particles. Significant differences in specific number and mass concentration or distributions were found among different methods and nano-powders with the most specific number and mass concentration and the smallest particles being generated by the most energetic SSPD, followed by VS and RD. Near uni-modal number or mass distributions were observed for the SSPD while bi-modal number or mass distributions existed for nano-powders except nano-SiO2 which also exhibited bimodal mass distributions. The 30-min average results showed that the mass median aerodynamic diameter (MMAD) and number median diameter (NMD) of the SSPD ranged 1.1-2.1 mu m and 166-261 nm, respectively, for all three nano-powders, which were smaller than those of the VS (MMAD: 3.3-6.0 mu m and NMD: 156-462 nm), and the RD (MMAD: 5.2-11.2 mu m and NMD: 198-479 nm). For nano-particles (electric mobility diameter < 100 nm), specific mass concentrations were nearly negligible for all three nano-powders and test methods. Specific number concentrations of nano-particles were low for the RD tester but were elevated when more energetic VS and SSPD testers were used. The quantitative size and concentration data obtained in this study is useful to elucidate the field emission and personal exposure data in the future provided that particle loss in the generation system is carefully assessed.Item type:Item, Exposure assessment of nano-sized and respirable particles at different workplaces(2011-09-01) ;Tsai, Chuen-Jinn ;Huang, Cheng-Yu ;Chen, Sheng-Chieh ;Ho, Chi-EnHuang, Cheng-HsiungIn this study, nanoparticle (NP, diameter < 100 nm) and respirable particles measurements were conducted at three different nanopowder workplaces, including the mixing area of a nano-SiO(2)-epoxy molding compound plant (primary diameter: 15 nm), bagging areas of a nano-carbon black (nano-CB) (primary diameter: 32 nm) and a nano-CaCO(3) (primary diameter: 94 nm) manufacturing plant. Chemical analysis of respirable particle mass (RPM) and NPs was performed to quantify the content of manufactured nanoparticles in the collected samples. Nanopowder products obtained from the plants were used in the laboratory dustiness testing using a rotating drum tester to obtain particle mass and number distributions. The obtained laboratory data were then used to elucidate the field data. Both field and laboratory data showed that NP number and mass concentrations of manufactured materials were close to the background level. Number concentration was elevated only for particles with the electrical mobility diameter > 100 nm during bagging or feeding processes, unless there were combustion-related incidental sources existed. Large fraction of nanomaterials was found in the RPM due to agglomeration of nanomaterials or attachment of nanomaterials to the larger particles. From this study, it is concluded that RPM concentration measurements are necessary for the exposure assessment of nanoparticles in workplaces.Item type:Item, Field Application of a Newly Developed Personal Nanoparticle Sampler to Selected Metalworking Operations(2013-06-01) ;Young, Li-Hao ;Lin, Yun-Hua ;Lin, Tzu-Hsien ;Tsai, Perng-JyWang, Ying-FangA personal nanoparticle sampler (PENS) that simultaneously collects respirable particles (< 4 mu m) and nanoparticles (< 0.1 mu m) has recently been developed and calibrated in the laboratory. This study aims to evaluate the performance of the PENS in the workplace, and to determine the exposure characteristics during selected metalworking operations. Metal polishing/buffing, spot welding, and milling operations were selected to represent sources of solid metal particles, fume aggregates and metalworking fluid mists, respectively. In each operation, personal samples of a side-by-side PENS and SKC respirable dust aluminum cyclone were taken concurrently with ambient particle number size distribution measurements. The PENS-measured respirable particle mass concentrations (PM4) showed remarkable accuracy with respect to the reference SKC cyclone, regardless of particle type. The PENS-derived nanoparticle effective densities agreed reasonably well with the bulk densities expected for the substrate and materials in use. During the metalworking operations, the nanoparticle mass concentrations (PM0.1) were poorly associated with the PM4 but strongly correlated with the ambient nanoparticle number concentrations (PN0.1), due to the persistent, elevated levels of nanoparticles formed during the operations. Overall, these results suggest that the PENS is applicable for use in the workplace to assess respirable and nanoparticle personal exposure, and that metal polishing/buffing, welding and milling generate a considerable amount of nanoparticles.Item type:Item, Measurements of respirable dust and nanoparticle concentrations in a titanium dioxide pigment production factory(2010) ;Huang, Cheng-Hsiung ;Tai, Chih-Yuan ;Huang, Cheng-Yu ;Tsai, Chuen-JinnChen, Chun-WanThis study compared respirable dust and nanoparticle concentrations measured by different sampling devices at a titanium dioxide pigment factory. Respirable particle mass concentrations, nanoparticle concentrations, particle size distribution and particle metallic content were measured at different sampling locations. The sampling results of the Multi-orifice Uniform Deposit Impactor (MOUDI) showed that the particle size distribution at this titanium dioxide production factory fell in the range of 1-10 mu m. Generally, the higher levels of the respirable particle mass concentrations and nanoparticle number concentrations were near the packing site of the pigment titanium dioxide production factory. Metal analysis results revealed that the titanium dioxide concentrations in respirable dust and nanoparticles were within the limits specified by National Institute for Occupational Safety and Health (NIOSH). During sampling, particle metallic content analysis is essential for identifying the source of particles and for measuring respirable dust and nanoparticle concentrations.Item type:Item, The Effect of Nanoparticle Convection-Diffusion Loss on the Transfer Function of an Aerosol Particle Mass Analyzer(2014) ;Lin, Guan-Yu ;Liao, Bo-Xi ;Tzeng, Neng-Jiun ;Chen, Chun-WanUang, Shi-NianThe existing theoretical response spectra of APM-3600 agree well with the experimental data for submicron particles larger than 100nm in the electrical mobility diameter but not for nanoparticles. In this study, a 2-D numerical model was developed to predict the transfer function and response spectra of APM-3600 based on the detailed simulation of flow and particle concentration fields. It was found that recirculation flows existed in the annular classifying region and APM\'s inlet and outlet regions, which led to enhanced convection-diffusion loss of nanoparticles compared to that without considering flow recirculation. As a result, the APM underestimates the mass of naonoparticles due to the shift of the peak position of the transfer function to a larger diameter than the targeted diameter. The response spectra calculated with the simulated transfer function agree well both in shapes and peak values with the experimental data present in a previous study for both nanoparticles and submicron particles larger than 100 nm. The predicted particle masses also agree well with the PSL\'s experimental data of the article.Copyright 2014 American Association for Aerosol Research