Browsing by Author "Chen, TK"
Now showing 1 - 11 of 11
- Results Per Page
- Sort Options
Item type:Item, 5 mm high-power-density dual-delta-doped power HEMT's for 3 V L-band applications(1996-05-01) ;Lai, YL ;Chang, EY ;Chang, CY ;Chen, TKLiu, THA high-power-density dual-delta-doped AlGaAs/InGaAs/GaAs high electron mobility transistor (HEMT) for personal communication applications has been developed. A 5.0 mm gate-width device operating at a drain bias of 3.0 V gave an output power over 1 W, The 1 mu m gate-length HEMT exhibited a current density of 425 mA/mm at V-gs = 0.5 V, The maximum transconductance of the device was 270 mS/mm, The effective knee voltage was as low as 0.3 V, At the class AB operation, the HEMT demonstrated an output power density of 200 mW/mm, 64% power-added efficiency and 18.2 dB linear gain at 900 MHz, This is the highest power density of a dual-delta-doped AlGaAs/InGaAs/GaAs HEMT reported to date for low voltage (3 V) wireless applications.Item type:Item, 5 mm high-power-density dual-delta-doped power HEMT's for 3 V L-band applications(1996-05-01) ;Lai, YL ;Chang, EY ;Chang, CY ;Chen, TKLiu, THA high-power-density dual-delta-doped AlGaAs/InGaAs/GaAs high electron mobility transistor (HEMT) for personal communication applications has been developed. A 5.0 mm gate-width device operating at a drain bias of 3.0 V gave an output power over 1 W, The 1 mu m gate-length HEMT exhibited a current density of 425 mA/mm at V-gs = 0.5 V, The maximum transconductance of the device was 270 mS/mm, The effective knee voltage was as low as 0.3 V, At the class AB operation, the HEMT demonstrated an output power density of 200 mW/mm, 64% power-added efficiency and 18.2 dB linear gain at 900 MHz, This is the highest power density of a dual-delta-doped AlGaAs/InGaAs/GaAs HEMT reported to date for low voltage (3 V) wireless applications.Item type:Item, Application of a membrane bioreactor system for opto-electronic industrial wastewater treatment - a pilot study(2003) ;Chen, TK ;Chen, JN ;Ni, CH ;Lin, GTChang, CYThe membrane bioreactor (MBR) system has become more and more attractive in the field of wastewater treatment. It is particularly attractive in situations where long solids retention times are required, such as nitrifying bacteria, and physical retention is critical to achieving more efficiency for biological degradation of pollutants. Although it is a new technology, the MBR process has been applied to industrial wastewater treatment for only the past decade. The opto-electronic industry, developed very fast over the past decade in the world, is a high technological manufacturing industry. The treatment of the opto-electronic industrial wastewater containing a significant quantity of organic nitrogen compounds, with a ratio over 95% in organic nitrogen (Org-N) to total nitrogen (T-N), is very difficult to meet the discharge limits. The purpose of this research is mainly to discuss the treatment capacity of high-strength organic nitrogen wastewater, and to investigate the capabilities of the MBR process. A 2 m(3)/day capacity MBR pilot plant consisting of anoxic and aerobic tanks and a membrane bioreactor was installed for evaluation. The operation was continued for 130 days. Over the whole experimental period, a satisfactory organic removal performance was achieved. The COD could be removed with an average of over 94.5%. For TOC and BOD5, the average removal efficiencies were 96.3 and 97.6%, respectively. The nitrification and denitrification were also successfully achieved. The effluent did not contain any suspended solids. Only a small concentration of ammonia nitrogen was found in the effluent. The stable effluent quality and satisfactory removal performance mentioned above were ensured by the efficient interception performance of the membrane device incorporated within the biological reactor. The MBR system shows promise as a means of treating very high organic nitrogen wastewater without dilution. The effluent of TKN, NOx-N and COD can fall below 20 mg/L, 30 mg/L and 50 mg/L.Item type:Item, Biological nitrification and denitrification of opto-electronic industrial wastewater(2003) ;Chen, TK ;Ni, CH ;Chen, LN ;環境工程研究所Institute of Environmental EngineeringDevelopment and application of biological nutrient removal processes accelerated significantly over the past decade due to more stringent nutrients (nitrogen and phosphorus) discharge limits being imposed on wastewater treatment plants. The opto-electronic industry has developed very fast over the past decade in the world. The wastewater often contains a significant quantity of organic nitrogen compounds and has a ratio of over 95% in organic nitrogen (Org-N) to total nitrogen (T-N). In this study, a 2-stage Anoxic/Aerobic pre-denitrification process was established and the efficiency of wastewater treatment was evaluated. Wastewater from an actual LCD-plant was obtained as the sample for looking into the feasibility of opto-electronic industrial wastewater treatment. Hydraulic retention time (HRT) and mixed liquor recycle rate (MLR) were controlled independently to distinguish between the effects of these two factors. Under suitable HRT and mixed liquor recycle ratio, effluents of NH4-N, NOx-N and COD can fall below 20 mg/l, 30 mg/l and 80 mg/l.Item type:Item, Combined membrane bioreactor (MBR) and reverse osmosis (RO) system for thin-film transistor - liquid crystal display TFT-LCD, industrial wastewater recycling(2004) ;Chen, TK ;Chen, JN ;環境工程研究所Institute of Environmental EngineeringIn TFT-LCD industry, water plays a variety of roles as a cleaning agent and reaction solvent. As good quality water is increasingly a scarce resource and wastewater treatment costs rises, the once-through use of industrial water is becoming uneconomical and environmentally unacceptable. Instead, recycling of TFT-LCD industrial wastewater is become more attractive from both an economic and environmental perspective. This research is mainly to explore the capacity of TFT-LCD industrial wastewater recycling by the process combined with membrane bioreactor and reverse osmosis processes. Over the whole experimental period, the MBR process achieved a satisfactory organic removal. The COD could be re,moved with an average of over 97.3%. For TOC and BOD5 items, the average removal efficiencies were 97.8 and 99.4% respectively. The stable effluent quality and satisfactory removal performance were ensured by the efficient interception performance of the UF membrane device incorporated with biological reactor. Moreover, the MBR effluent did not contain any suspended solids and the SDI value was under 3. Aftr treatment of RO, excellent water quality of permeate were under 5 mg/l, 2.5 mg/l and 150 mus/cm for COD, TOC and conductivity respectively. The treated water can be recycled for the cooling tower make-up water or other purposes.Item type:Item, High-strength nitrogen removal of opto-electronic industrial wastewater in membrane bioreactor - a pilot study(2003) ;Chen, TK ;Ni, CH ;Chen, JN ;Lin, J環境工程研究所The membrane bioreactor (MBR) system has become more and more attractive in the field of wastewater treatment. It is particularly attractive in situations where long solids retention times are required, such as nitrifying bacteria, and physical retention critical to achieving more efficiency for biological degradation of pollutant. Although it is a new technology, the MBR process has been applied for industrial wastewater treatment for only the past decade. The opto-electronic industry, developed very fast over the past decade in the world, is high technology manufacturing. The treatment of the opto-electronic industrial wastewater containing a significant quantity of organic nitrogen compounds with a ratio over 95% in organic nitrogen (Org-N) to total nitrogen (T-N) is very difficult to meet the discharge limits. This research is mainly to discuss the treatment capacity of high-strength organic nitrogen wastewater, and to investigate the capabilities of the MBR process. A 5 m(3)/day capacity of MBR pilot plant consisted of anoxic, aerobic and membrane bioreactor was installed for evaluation. The operation was continued for 150 days. Over the whole experimental period, a satisfactory organic removal performance was achieved. The COD could be removed with an average of over 94.5%. For TOC and BOD5 items, the average removal efficiencies were 96.3 and 97.6%, respectively. The nitrification and denitrification was also successfully achieved. Furthermore, the effluent did not contain any suspended solids. Only a small concentration of ammonia nitrogen was found in the effluent. The stable effluent quality and satisfactory removal performance mentioned above were ensured by the efficient interception performance of the membrane device incorporated within the biological reactor. The MBR system shows promise as a means of treating very high organic nitrogen wastewater without dilution. The effluent of TKN, NOx-N and COD can fall below 20 mg/L, 30 mg/L and 50 mg/L.Item type:Item, MBR/RO/ozone processes for TFT-LCD industrial wastewater treatment and recycling(2005) ;Chen, TK ;Ni, CH ;Chan, YC ;Lu, MC環境工程研究所This research is mainly to explore the treatment capacity for TFT-LCD industrial wastewater recycling by the processes combined with membrane bioreactor (MBR), reverse osmosis (RO) and ozone(03). The organic wastewater from the TFT-LCD industry was selected as the target. MBR, RO and ozone plants were established for evaluation. An MBR plant consisted of a 2-stage anoxic/aerobic bioreactor and an immersed UF membrane unit was employed. The effluent of MBR was conducted into the RO system then into the ozone system. The RO system consisted of a spiral membrane in the vessel. One bubble column, 75 cm high and diameter 5 cm, were used as the ozonation reactor. On the bottom of ozonation reactor is a porous diffuser for releasing gas, with an aperture of 100 mu m (0.1 cm). Over the whole experimental period, the MBR process achieved a satisfactory organic removal. The COD could be removed with an average of over 98.5%. For the TOC item, the average removal efficiency was 97.4%. The stable effluent quality and satisfactory removal performance were ensured by the efficient interception performance of an immersed UF membrane device incorporated with the biological reactor. Moreover, the MBR effluent did not contain any suspended solids and the SDI value was under 3. After the treatment of RO, excellent water quality was found. The water quality of permeate was under 5 mg/l, 2 mg/l and 50 mu s/cm for COD, TOC and conductivity respectively. The treated water can be recycled and reused for the cooling tower make-up water or other purposes. After the treatment of ozone, the treated water quality was under 5 mg/l and 0.852 mg/l for COD and TOC respectively. The test results of MBR, MBR/RO and MBR/RO/ozone processes were compared as possible appropriate treatment technologies applied in TFT-LCD industrial wastewater reuse and recycling.Item type:Item, Nitrification-denitrification of opto-electronic industrial wastewater by anoxic/aerobic process(2003) ;Chen, TK ;Ni, CH ;Chen, JN ;環境工程研究所Institute of Environmental EngineeringThis research focused on the biological treatment of high-strength organic nitrogen wastewater, and presented the results from the nitrification and denitrification of an actual industrial wastewater using anoxic/aerobic process, The opto-electronic industrial wastewater often contains a significant quantity of organic nitrogen compounds and has a ratio over 95% in organic nitrogen (Org-N) to total nitrogen (T-N). In this study, a 2-stage anoxic/aerobic process was established and evaluated the efficiency of wastewater treatment. Raw wastewater from an actual TFT-LCD manufacturing plant was obtained as the sample for looking into the feasibility of opto-electronic industrial wastewater treatment. After toxicity identification evaluation (TIE) test of raw wastewater, the inhibition was related to organic nitrogen (TMAH, MEA) and unionized ammonia (free ammonia, NH3) with high pH. Therefore, pH control is important for biological treatment of high-strength organic nitrogen industrial wastewater. Besides, hydraulic retention time (HRT) and mixed liquor recycled rate (MLR) were controlled independently to distinguish between the effects of these two factors. Under suitable HRT (> 1.7d) and mixed liquor recycled rate (< 4Q). effluent of Nh(4)-N, No-3-N+NO2-N, and COD can fall below 20mg/L, 30mg/L, and 80 mg/L. The anoxic/aerobic process removed 92-98% of the carbon source, and approximately 80% of TKN, 70% of T-N.Item type:Item, Recycling and reuse of wastewater from a new-developed community using sand filtration, ultrafiltration, and ozonation(2003) ;Ni, CH ;Chen, JN ;Tsai, YC ;Chen, TKChen, WBIn this study, the pilot apparatus combined with sand filtration, ozonation and ultrafiltration was established. Wastewater from the secondary treatment effluent in the new-developed community was taken as the sample for looking into the feasibility of domestic wastewater reuse and recycling. The test results by sand filtration, sand filtration/ultrafiltration, sand filtration/ozonation, and sand filtration/ultrafiltration/ozonation were compared for looking for appropriate treatment processes applied in the domestic wastewater reuse and recycling, Finally, cost analysis was carried out and sand filtration/ozonation process was suggested to be one of the best processes. The total cost is about 0.1-0.32 $USD per cubic meter of produced water by considering the capital and operation cost for five years in the small domestic wastewater treatment plant (50-750 CMD).Item type:Item, Synthesis and characterization of novel segmented polyurethane clay nanocomposite via poly(epsilon-caprolactone)/clay(1999-07-01) ;Chen, TK ;Tien, YI ;Wei, KH ;材料科學與工程學系Department of Materials Science and EngineeringA novel segmented polyurethane/clay (PU/clay) nanocomposite based on poly(caprolactone), diphenylmethane diisocyanate, butanediol, and poly(caprolactone)/ clay prepolymer was synthesized as evidenced by FTIR and X-ray diffraction studies. Poly(caprolactone)/clay (PCL/clay) prepolymer was first synthesized in a nanocomposite form as confirmed by X-ray diffraction. X-ray diffraction study showed that PU/clay contained crystalline structure due to the presence of PCL/clay. In mechanical properties, about 1.4% PCL/clay in PU/clay resulted in a large increase in the elongation of PU/clay. However, when the amount of PCL/clay was 4.2%, the elongation of PU/clay was reduced drastically. This behavior indicated that PU/clay can be transformed from an elastomer to a thermoplastic material as the amount of PCL/clay in PU/clay increased. Additionally, the lap shear stress of PU/clay was at least three times that of neat PU as a result of the PCL/clay component. (C) 1999 John Wiley & Sons, Inc. J Polym Sci A: Polym Chem 37: 2225-2233, 1999.Item type:Item, Synthesis and characterization of novel segmented polyurethane/clay nanocomposites(2000-02-01) ;Chen, TK ;Tien, YI ;Wei, KH ;材料科學與工程學系Department of Materials Science and EngineeringA novel segmented polyurethane(Pu)/clay nanocomposite has been synthesized by polyurethane and organoclay. 12 aminolauric acid (12COOH) and benzidine (BZD) were used as swelling agents to treat Na+-montmorillonite and for forming organoclay (12COOH-mont acid BZD-mont) through ion exchange. The nanometer-scale silicate layers of organoclay were completely exfoliated in PU in the cases of 1, 3 and 5% 12COOH-mont/PU and in the cases of 1 and 3% BZD-mont/PU nanocomposites as confirmed by X-ray diffraction pattern and transmission electron microscopy studies. The segmented structures of PU were not interfered by the presence of the silicate layers in these nanocomposites as evidenced by their glass transition and degree of phase separation from differential scanning calorimetry and Fourier transform infrared measurements. A two-fold increase in the tensile strength and a three-fold increase in the elongation were found for 1% BZD-mont/PU as compared to that of pure PU. Additionally, both 1% 12COOH-mont/PU and 1% BZD-mont/PU exhibited lower water absorption properties than that of pure PU. (C) 1999 Elsevier Science Ltd. All rights reserved.