Browsing by Author "Cheng, Cheng-Hsiang"
Now showing 1 - 8 of 8
- Results Per Page
- Sort Options
Item type:Item, A 16-Channel CMOS Chopper-Stabilized Analog Front-End Acquisition Circuits for ECoG Detection(2017-01-01) ;Cheng, Cheng-Hsiang ;Chen, Zhi-Xin ;Wu, Chung-Yu ;電子工程學系及電子研究所生醫電子轉譯研究中心In this paper, a 16-channel analog front-end (AFE) ECoG-signal acquisition circuit for closed-loop seizure control system is presented. It is composed of 16 auto-reset chopper-stabilized capacitive-coupled instrumentation amplifiers (AR-CSCCIA) with band-pass filters, 16 programmable transconductance-gain amplifiers, a multiplexer, a transimpedance amplifier, and a 10-bit SAR ADC. The low input-referred noise is achieved by using chopper modulation technique in AR-CSCCIA. To reduce the undesired effects of chopper modulation, an improved offset reduction loop (ORL) is proposed to reduce output offset generated by input chopper mismatches. The digital ripple reduction loop (RRL) is also used to reduce chopper ripple. Moreover, to prevent from overstress in MOS devices caused by high stimulation voltage, an input protection circuit with high-voltage-tolerant switches is proposed to make the AFE amplifiers sharing the same electrode with high voltage stimulators. The fabricated AFE acquisition circuit has 49.1/59.1/67.9 dB programmable gain and 2.09uV(rms) input referred noise in a bandwidth 0.5-100 Hz. The measured power consumption of AFE is 3.26 uW per channel and the noise efficiency factor (NEF) is 3.78.Item type:Item, A 16-Channel CMOS Chopper-Stabilized Analog Front-End ECoG Acquisition Circuit for a Closed-Loop Epileptic Seizure Control System(2018-06-01) ;Wu, Chung-Yu ;Cheng, Cheng-Hsiang ;Chen, Zhi-Xin ;電子工程學系及電子研究所生醫電子轉譯研究中心In this paper, a 16-channel analog front-end (AFE) electrocorticography signal acquisition circuit for a closed-loop seizure control system is presented. It is composed of 16 input protection circuits, 16 auto-reset chopper-stabilized capacitive-coupled instrumentation amplifiers (AR-CSCCIA) with bandpass filters, 16 programmable transconductance gain amplifiers, a multiplexer, a transimpedance amplifier, and a 128-kS/s 10-bit delta-modulated successive-approximation-register analog-todigital converter (SAR ADC). In closed-loop seizure control system applications, the stimulator shares the same electrode with the AFE amplifier for effective suppression of epileptic seizures. To prevent from overstress in MOS devices caused by high stimulation voltage, an input protection circuit with a high-voltage-tolerant switch is proposed for the AFE amplifier. Moreover, low input-referred noise is achieved by using the chopper modulation technique in the AR-CSCCIA. To reduce the undesired effects of chopper modulation, an improved offset reduction loop is proposed to reduce the output offset generated by input chopper mismatches. The digital ripple reduction loop is also used to reduce the chopper ripple. The fabricated AFE amplifier has 49.1-/59.4-/67.9-dB programmable gain and 2.02-mu Vrms input referred noise in a bandwidth of 0.59-117 Hz. The measured power consumption of the AFE amplifier is 3.26 mu W per channel, and the noise efficiency factor is 3.36. The in vivo animal test has been successfully performed to verify the functions. It is shown that the proposed AFE acquisition circuit is suitable for implantable closed-loop seizure control systems.Item type:Item, A Bone-Guided Cochlear Implant CMOS Microsystem Preserving Acoustic Hearing(2017-01-01) ;Qian, Xin-Hong ;Wu, Yi-Chung ;Yang, Tzu-Yi ;Cheng, Cheng-HsiangChu, Hsing-ChienIn this paper, a bone-guided cochlear implant (BGCI) SOC microsystem is proposed and designed. The BGCI microsystem uses four or more electrodes placed on the bone surface of the cochlea and one on the round window to preserve partially the acoustic hearing. The external SOC of the BGCI processes the acoustic signals and generates stimulation patterns and command that are transmitted to the implanted chip through the 13.56MHz wireless power and bidirectional data telemetry. The implanted chip with 4-channel high-voltage-tolerant stimulator generates biphasic stimulation currents up to 800 mu A and sends back the power indication and electrode impedance error signals to the external SOC. Electrical tests on the fabricated BGCI has been performed. The in-vivo animal tests on guinea pigs has shown the evoked Wave III of EABR waveforms. The proposed BGCI can be applied to patients with high-frequency hearing loss, tinnitus, and dizziness.Item type:Item, A Fully Integrated 16-Channel Closed-Loop Neural-Prosthetic CMOS SoC With Wireless Power and Bidirectional Data Telemetry for Real-Time Efficient Human Epileptic Seizure Control(2018-11-01) ;Cheng, Cheng-Hsiang ;Tsai, Ping-Yuan ;Yang, Tzu-Yi ;Cheng, Wan-HsuehYen, Ting-YangA 16-channel closed-loop neuromodulation system-on-chip (SoC) for human epileptic seizure control is proposed and designed. In the proposed SoC, a 16-channel neural-signal acquisition unit (NSAU), a biosignal processor (BSP), a 16-channel high-voltage-tolerant stimulator (HVTS), and wireless power and bidirectional data telemetry are designed. In the NSAU, the input protection circuit is used to prevent MOSFET from overstressing by the high-voltage stimulations. Hence, NSAUs can share electrodes with stimulators. The auto-reset chopper-stabilized capacitive-coupled instrumentation amplifiers (AR-CSCCIAs) are designed with the chopper-stabilized technique with a new offset reduction loop. The measured input-referred noise is 2.09 mu V-rms and the noise-efficiency factor (NEF) is 3.78. The entropy-and-spectrum seizure detection algorithm is implemented in the BSP with 0.76-s seizure detection latency and 97.8% detection accuracy. When the seizure onset is detected by the BSP, the HVTS with adaptive supply control delivers 0.5-3-mA biphasic current stimulation to suppress the seizure onset. The proposed SoC is powered wirelessly, and the bidirectional data telemetry is realized through the same pair of coils in 13.56 MHz. The downlink data rate is 211 Kb/s with the binary phase-shift keying (BPSK) modulation and a new BPSK demodulator. The uplink data rate is 106 Kb/s with the load-shift keying (LSK) modulation. The proposed SoC is fabricated in a 0.18-mu m CMOS technology and occupies 25 mm(2). Electrical tests have been performed to characterize the SoC performance. In vivo animal experiments using mini-pigs have been performed to successfully verify the closed-loop neuromodulation functions on epileptic seizure suppression.Item type:Item, A Fully Integrated Closed-Loop Neuromodulation SoC with Wireless Power and Bidirectional Data Telemetry for Real-Time Human Epileptic Seizure Control(2017-01-01) ;Cheng, Cheng-Hsiang ;Tsai, Ping-Yuan ;Yang, Tzu-Yi ;Cheng, Wan-HsuehYen, Ting-YangThis paper presents a 16-channel closed-loop neuromodulation SoC for human seizure control. The SoC includes a 16-ch signal acquisition unit, a bio-signal processor, a 16-ch adaptive stimulator, and wireless telemetry. The signal acquisition unit achieves 3.78 NEF and shares electrodes with stimulator. The seizure detection latency is 0.76s and delivered 0.5-3mA biphasic current stimulation. The SoC is powered wirelessly and bidirectional data telemetry is realized through the same pair of coils in 13.56MHz.Item type:Item, Design and In Vivo Verification of a CMOS Bone-Guided Cochlear Implant Microsystem(2019-11-01) ;Qian, Xin-Hong ;Wu, Yi-Chung ;Yang, Tzu-Yi ;Cheng, Cheng-HsiangChu, Hsing-ChienObjective: To develop and verify a CMOS bone-guided cochlear implant (BGCI) microsystem with electrodes placed on the bone surface of the cochlea and the outside of round window for treating high-frequency hearing loss. Methods: The BGCI microsystem consists of an external unit and an implanted unit. The external system-on-chip is designed to process acoustic signals through an acquisition circuit and an acoustic DSP processor to generate stimulation patterns and commands that are transmitted to the implanted unit through a 13.56 MHz wireless power and bidirectional data telemetry. In the wireless power telemetry, a voltage doubler/tripler (2X/3X) active rectifier is used to enhance the power conversion efficiency and generate 2 and 3 V output voltages. In the wireless data telemetry, phase-locked loop based binary phase-shift keying and load-shift keying modulators/demodulators are adopted for the downlink and uplink data through high-Q coils, respectively. The implanted chip with four-channel high-voltage-tolerant stimulator generates biphasic stimulation currents up to 800 mu A. Results: Electrical tests on the fabricated BGCI microsystem have been performed to verify the chip functions. The in vivo animal tests in guinea pigs have shown the evoked third wave of electrically evoked auditory brainstem response waveforms. It is verified that auditory nerves can be successfully stimulated and acoustic hearing can be partially preserved. Conclusion and Significance: Different from traditional cochlear implants, the proposed BGCI microsystem is less invasive, preserves partially acoustic hearing, and provides an effective alternative for treating high-frequency hearing loss.Item type:Item, Design Considerations and Clinical Applications of Closed-Loop Neural Disorder Control SoCs(2017-01-01) ;Wu, Chung-Yu ;Cheng, Cheng-Hsiang ;Ou-Yang, Yi-Huan ;Chen, Chiung-ChuChen, Wei-MingThis paper presents the closed-loop neural disorder control concept and some design considerations. Two architectures of closed-loop neuromodulation for Parkinson's disease and epileptic seizure are proposed. One is a closed-loop deep brain stimulator, which meets the IEC 60601-1 standard. The other one is an implantable SoC for epileptic seizure control, which is verified by animal experiment.Item type:Item, Subretinal prosthetic systems and epileptic seizure control systems: Chip design, integration, and animal tests(2018-10-01) ;Wu, Chung-Yu ;Tseng, Chi-Kuan ;Cheng, Cheng-Hsiang ;電子工程學系及電子研究所生醫電子轉譯研究中心In this paper, both implantable subretinal prosthetic systems and closed-loop epileptic seizure control systems reported in the literature are analyzed and reviewed in the terms of chip design, integration, and animal tests. In the review of subretinal prosthetic systems, the four main parts, image sensing, stimulation, data/power transfer, and implantation, are investigated and compared. The review is followed by a comparison to provide a summary. The future challenges and the development of bio-subretinal chips with retinal cells grown on chips are also presented. In the review of state-of-the-art papers on closed-loop epileptic seizure control systems and system on chips (SoCs), the four main parts, the neuralsignal amplifier, biosignal processor, stimulator, and wireless telemetry, are investigated with the design requirements and advantages/shortcomings. The review is summarized by a performance comparison table. It can be seen that the closed-loop epileptic-seizure-control SoCs have advanced to clinical applications on humans. Both reviewed implantable systems will be important milestones for future bioelectronic medicine. (C) 2018 The Japan Society of Applied Physics