Browsing by Author "Chiang, Hsuan-Ping"
Now showing 1 - 2 of 2
- Results Per Page
- Sort Options
Item type:Item, Tooth bleaching by using a helium-based low-temperature atmospheric pressure plasma jet with saline solution(2017-11-01) ;Cheng, Yun-Chien ;Wu, Chia-Hua ;Liu, Chih-Tung ;Lin, Chia-YungChiang, Hsuan-PingIn this study, tooth bleaching was performed by using a helium-based low temperature atmospheric-pressure plasma jet (He-APPJ) with saline solution to avoid ozone and hydrogen peroxide (H2O2) harm. In this study, tooth samples were treated through three approaches, namely a helium flow with saline, H2O2 gel, and He-APPJ with saline. The bleaching efficacy of the He-APPJ treatment was the highest among the three groups. Furthermore, scanning electron microscopy images showed that enamel treated with He-APPJ was much less damaged than that treated with H2O2 gel. In addition, ozone tests showed that APPJ produced little ozone (<0.35ppm). In conclusion, He-APPJ with saline solution achieves higher bleaching efficacy and is less harmful than methods that use H2O2 gel.Item type:Item, Using Micro-Molding and Stamping to Fabricate Conductive Polydimethylsiloxane-Based Flexible High-Sensitivity Strain Gauges(2018-02-01) ;Han, Chi-Jui ;Chiang, Hsuan-Ping ;Cheng, Yun-Chien ;機械工程學系Department of Mechanical EngineeringIn this study, polydimethylsiloxane (PDMS) and conductive carbon nanoparticles were combined to fabricate a conductive elastomer PDMS (CPDMS). A high sensitive and flexible CPDMS strain sensor is fabricated by using stamping-process based micro patterning. Compared with conventional sensors, flexible strain sensors are more suitable for medical applications but are usually fabricated by photolithography, which suffers from a large number of steps and difficult mass production. Hence, we fabricated flexible strain sensors using a stamping-process with fewer processes than photolithography. The piezoresistive coefficient and sensitivity of the flexible strain sensor were improved by sensor pattern design and thickness change. Micro-patterning is used to fabricate various CPDMS microstructure patterns. The effect of gauge pattern was evaluated with ANSYS simulations. The piezoresistance of the strain gauges was measured and the gauge factor determined. Experimental results show that the piezoresistive coefficient of CPDMS is approximately linear. Gauge factor measurement results show that the gauge factor of a 140.0 mu m thick strain gauge with five grids is the highest.