Browsing by Author "Chu, Chao-Yu"
Now showing 1 - 3 of 3
- Results Per Page
- Sort Options
Item type:Item, LC-lens array with light field algorithm for 3D bio-medical applications(2016-01-01) ;Huang, Yi-Pai ;Hsieh, Po-Yuan ;Hassanfiroozi, Amir ;Martinez, ManuelJavidi, BahramIn this paper, liquid crystal lens (LC-lens) array was utilized in 3D bio-medical applications including 3D endoscope and light field microscope. Comparing with conventional plastic lens array, which was usually placed in 3D endoscope or light field microscope system to record image disparity, our LC-lens array has higher flexibility of electrically changing its focal length. By using LC-lens array, the working distance and image quality of 3D endoscope and microscope could be enhanced. Furthermore, the 2D/3D switching ability could be achieved if we turn off/on the electrical power on LC-lens array. In 3D endoscope case, a hexagonal micro LC-lens array with 350um diameter was placed at the front end of a 1mm diameter endoscope. With applying electric field on LC-lens array, the 3D specimen would be recorded as from seven micro-cameras with different disparity. We could calculate 3D construction of specimen with those micro images. In the other hand, if we turn off the electric field on LC-lens array, the conventional high resolution 2D endoscope image would be recorded. In light field microscope case, the LC-lens array was placed in front of the CMOS sensor. The main purpose of LC-lens array is to extend the refocusing distance of light field microscope, which is usually very narrow in focused light field microscope system, by montaging many light field images sequentially focusing on different depth. With adjusting focal length of LC-lens array from 2.4mm to 2.9mm, the refocusing distance was extended from 1mm to 11.3mm. Moreover, we could use a LC wedge to electrically shift the optics axis and increase the resolution of light field.Item type:Item, Liquid crystal lens array for 3D microscopy and endoscope application(2016-01-01) ;Huang, Yi-Pai ;Hsieh, Po-Yuan ;Hassanfiroozi, Amir ;Chu, Chao-YuHsuan, YunIn this paper, we demonstrate two liquid crystal (LC) lens array devices for 3D microscope and 3D endoscope applications respectively. Compared with the previous 3D biomedical system, the proposed LC lens arrays are not only switchable between 2D and 3D modes, but also are able to adjust focus in both modes. The multi-function liquid crystal lens (MFLC-lens) array with dual layer electrode has diameter 1.42 mm, which is much smaller than the conventional 3D endoscope with double fixed lenses. The hexagonal liquid crystal micro-lens array (HLC-MLA) instead of fixed micro-lens array in 3D light field microscope can extend the effective depth of field from 60 um to 780 um. To achieve the LC lens arrays, a high-resistance layer needs to be coated on the electrodes to generate an ideal gradient electric-field distribution, which can induce a lens-like form of LC molecules. The parameters and characteristics of high-resistance layer are investigated and discussed with an aim to optimize the performance of liquid crystal lens arrays.Item type:Item, Long working range light field microscope with fast scanning multifocal liquid crystal microlens array(2018-04-16) ;Hsieh, Po-Yuan ;Chou, Ping-Yen ;Lin, Hsiu-An ;Chu, Chao-YuHuang, Cheng-TingThe light field microscope has the potential of recording the all information of biological specimens in real time with a conventional light source. To further extend the depth of field to broaden its applications, in this paper, we proposed a multifocal high-resistance liquid crystal microlens array instead of the fixed microlens array. The developed multifocal liquid crystal microlens array can provide high quality point spread function in multiple focal lengths. By adjusting the focal length of the liquid crystal microlens array sequentially, the total working range of the light field microscope can be much extended. Furthermore, in our proposed system, the intermediate image was placed in the virtual image space of the microlens array, where the condition of the lenslets numerical aperture was considerably smaller. Consequently, a thin-cell-gap liquid crystal microlens array, with fast response time can be implemented for time-multiplexed scanning. (C) 2018 Optical Society of America under the terms of the OSA Open Access Publishing Agreement