Browsing by Author "Elpa, Decibel P."
Now showing 1 - 2 of 2
- Results Per Page
- Sort Options
Item type:Item, Automation of mass spectrometric detection of analytes and related workflows: A review(2020-02-01) ;Elpa, Decibel P. ;Prabhu, Gurpur Rakesh D. ;Wu, Shu-Pao ;Tay, Kheng SooUrban, Pawel L.The developments in mass spectrometry (MS) in the past few decades reveal the power and versatility of this technology. MS methods are utilized in routine analyses as well as research activities involving a broad range of analytes (elements and molecules) and countless matrices. However, manual MS analysis is gradually becoming a thing of the past. In this article, the available MS automation strategies are critically evaluated. Automation of analytical workflows culminating with MS detection encompasses involvement of automated operations in any of the steps related to sample handling/treatment before MS detection, sample introduction, MS data acquisition, and MS data processing. Automated MS workflows help to overcome the intrinsic limitations of MS methodology regarding reproducibility, throughput, and the expertise required to operate MS instruments. Such workflows often comprise automated off-line and on-line steps such as sampling, extraction, derivatizadon, and separation. The most common instrumental tools include autosamplers, multi-axis robots, flow injection systems, and lab-on-a-chip. Prototyping customized automated MS systems is a way to introduce non-standard automated features to MS workflows. The review highlights the enabling role of automated MS procedures in various sectors of academic research and industry. Examples include applications of automated MS workflows in bioscience, environmental studies, and exploration of the outer space.Item type:Item, Rapid Extraction and Analysis of Volatile Solutes with an Effervescent Tablet(2020-02-04) ;Elpa, Decibel P. ;Wu, Shu-Pao ;Urban, Pawel L. ;交大名義發表National Chiao Tung UniversityExtraction of volatile compounds from complex liquid matrices is a critical step in volatile compound analysis workflows. Recently, green chemistry principles are increasingly implemented in extraction processes. Some of the available approaches are solvent-free but still require concentration or trapping of analytes. Here, we propose effervescent tablet-induced extraction (ETIE) as a method of transferring volatile/semivolatile compounds from liquid matrices to the gas phase for analysis. This technique relies on the release of carbon dioxide produced in situ during a neutralization reaction, which occurs when a tablet is inserted into an aqueous sample matrix. In this process, many bubbles of carbon dioxide are instantly formed in the sample matrix. The bubbles rapidly extract and liberate volatile compounds from the sample. The gaseous effluent is then immediately transferred to a detector (atmospheric pressure chemical ionization mass spectrometry (MS) or gas chromatography (GC) hyphenated with MS). ETIE-GC-MS can be used for analysis of volatile compounds present in real samples. The method was validated for analysis of selected ethyl esters present in a yogurt drink. The calibration data set was linear over a range from 5 x 10(-7) to 1 X 10(-5) M. The limits of detection ranged from 1.51 X 10(-7) to 6.82 X 10(-7) M, while the recoveries ranged from 71 to 118%. Inter- and intraday precision of selected ethyl esters in aqueous solution was satisfactory (relative standard deviation, 3.6-18.3%). Furthermore, it is shown that ETIE improves the performance of headspace solid-phase microextraction while eliminating the need for heating and shaking samples.